Wiring:
Panel cutout (rear side):
Strip the wires.
Insert wires to terminals and tighten.
*
ATTENTION:
Max torque 130 cNm
PowerCON HC
Assembled Connector
1. Push insert and chuck into housing.
2. Tighten bushing using open wrench 27 mm,
min. torque 3.5 Nm.
Important: Align the chuck and insert by
positioning the nose into keyway.
[0.394"]
10 mm
N
White
PE
Green
L
Black
D
D
1.
2.
25.0
30.0
Ø
30.0
Ø
3.8
Note:
Conductor colors according to color coding of North American cords.
1.
2.
Draft. Nr.: BDA 178
Update:
22.07.2008
/ 3102M1481
I
I
Data subject to change without prior notice. 2008 NEUTRIK . ALL RIGHTS RESERVED.
©
®