NEUTRIK opticalCON FOCD-STC Скачать руководство пользователя страница 1

CLEANING INSTRUCTION

®

optical

CON

 Chassis Connector

Cleaning Adapter FOCD-STC & FOID-STQC

R

Cassis Cleaning / Inspection

CAUTION:
Laser radiation, do not look directly into beam of light!

Intervall: 

 

every 500 matings recommended

®

Tools: 

 

Neutrik  Chassis Cleaning Adapter: 

 FOCD-STC / FOID-STQC

 

 

Dry Cleaner: 

 

 

 

 FOCD-DC125, FOCD-DCM

 

 

Optical fiber video probe

®

optical

CON

 DUO Chassis Cleaning

®

Insert the FOCD-STC in to the Neutrik opticalCON  
NO2-4FDW-A-* chassis. 

Use  the  appropriate  tip  for  the  video  probe 
according to the matrix on the last page. 

Then inspect the LC surface.

After inspection clean the LC surface with the Dry 
Cleaner 1.25 mm.  

Check the condition of the LC ferrule surface again 
and if necessary, repeat step  A  and  B  .

Page 1

BDA 636 V1

LASER

1

The sealing shutter mechanism of the optical

CON

 avoids contamination of the LC ferrule locked inside.

®

The dust-proof design reduces maintenance intervals to a minimum; if nevertheless necessary, 

follows the maintenance procedure below to avoid damages on the due to inpropes cleaning.

1.

Video probe tip

Dry Cleaner

A

B

A

B