Container Cleaning System TANKO®EX-R64T
5 Installation
Translation - Operating/installation instructions 2020/03
43/80
WARNING
Danger due to swinging hydraulic equipment!
In certain operating states, screw and clamp connections could unforeseeably be
released due to significant swinging and/or vibrations. This means it is possible for leaks
to develop at the sealed points of the connections and line connections, from which hot
and/or caustic fluid could be expelled at high pressure.
There is a risk of death or severe physical injury.
All connections and line connections should be safely attached without mechanical
tension and sealed technically permanently.
During initial start-up, the swinging and vibrations of the device must always be
observed and, insofar as is possible, tested under various operating conditions.
In the event of swinging and/or vibrations, avoid releasing the connections by
additional measures, such as spot welding or bonding (e.g. Loctite).
5.2
Installation
The safety instructions in
Section 5.1 Safety Instructions for Installation
must be adhered to before
installation of the device in the container.
CAUTION
Fault due to incorrect installation position/location of the device!
Any installation of the device NOT performed correctly can cause damage to the device
which puts the functional safety and reliability at risk during start-up.
That can result in hazards.
There is a risk of minor or moderate injuries.
When selecting the installation position of the device, make sure that
a safe distance is maintained from the internal wall of the container and from
nearby components, in order to prevent scraping or impact during operation and
to prevent collisions while the cleaning head and surrounding components (e.g.
agitators) are moving simultaneously.
Only a fixed pipe installation is permitted. Installation of a hose can cause the installed
cleaning device to thrash/hit about.
Install the device free of mechanical tension.
Take the installation dimensions from
Section
drawing of the AWH catalog or the device drawing.
Ensure sufficient space for operation and maintenance.