Chapter 2
Planning Repeater Installation
T
his chapter contains information that will help you prepare for installing the
Micro 100-TX24
repeater. This includes
installation requirements and system planning charts.
Installation Requirements
To help ensure a correct installation, read this section to determine the environmental, electrical, spatial, and cable
requirements.
Environmental Requirements
Be sure the operating environment for the repeater is within the following ranges:
t
Temperature: 32º to 122ºF (0º to 50ºC)
t
Humidity: 5% to 95% (non-condensing)
t
Altitude: 0 to 10,000 feet (0 to 3 km)
t
Clearance: minimum of 2 inches (5.1 centimeters) on each side of the repeater for proper ventilation
Electrical Requirements
The electrical requirements for a
Micro 100-TX24
repeater are as follows:
t
100 240 VAC
t
1.5 0.75 Amps (1.5A @ 100 VAC 0.75A @ 240 VAC)
t
50 60 Hz
Caution: The power outlet must be a non-switched, three-pronged, grounded outlet. Do not use a
three-to-two pronged adapter at the outlet. Doing so may result in electrical shock and/or damage to
the repeater and will void your warranty.
Note: If the supplied power cord is lost or damaged, replace it with a power cord of the same type and
current rating (10A). The replacement cord should also meet required regulatory approvals to ensure
emissions compliance.