TABLE OF CONTENTS

Before You Start

1

Introduction

1

What is in the box?

1

Copyright Notice

1

Thermostat Callout

1

Thermostat Location

1

Mount Thermostat Backplate

1

Thermostat Setup

2

Touchscreen User Menu Settings

2

Touchscreen Installer Menu Settings

2

Touchscreen Temperature Override

2

Additional Settings and Features

2

Remote Sensors (optional)

3

Programming The Thermostat

3

Wiring Diagrams

3

Terminal Connection Callouts

3

Independent Power Source (Optional)

3

Wiring Diagram Cross Reference Chart

4

Specifications

4

FIVE (5) Year Limited Warranty

4

FCC Regulatory Information

4

BEFORE YOU START

Please read entire install manual. The thermostat will need to

be correctly wired and configured for proper operation. Basic

HVAC configuration can be performed from the thermostat

touchscreen and advanced settings are accessed via your

network and/or the Internet.

INTRODUCTION

The X-Series thermostat is a network connected color

touchscreen thermostat with an advanced remote sensor bus,

designed for new or replacement commercial or residential

applications. It supports up to 3 Heat / 2 Cool heat pumps and

2 Heat / 2 Cool conventional systems. Internal webpages help

deliver a near-effortless setup of your daily schedules (4 events

per day), and up to 40 Special and 40 Calendar Events. The

unique scheduling structure also supports the powerful

features of adjustable temporary override times, temperature

ranges, occupied and unoccupied events, keypad lockout, and

many more features.
Available in both Wi-Fi and Ethernet models, the X-Series

supports NetX CloudConnect™, DirectConnect™, and

PCConnect™ Software Tools.

Core Features

4 independent schedules per day

40 Calendar Event Schedules

40 Special Event Schedules

Integrated Humidity Sensor

Integrated Weather with Current Conditions & 7-Day Forecasts

Occupancy Sensor Input

14 Remote Sensors: up to 6 indoor, 1 humidity, 1 outdoor,

and up to 3 auxiliary sensors for monitoring items such as

supply air, return air, walk-in refrigerators and freezers, etc.

2 Digital Inputs for Fault Conditions, including Condensate

and Equipment Faults

Email & Text Message Alerting for 4 Recipients

Alerts include Hi/Lo Temps for Indoor, Outdoor, Supply,

Return, and Aux Temps, Inefficient Equipment Runs, Change

Filter Notifications, and Two Digital Inputs: 19 Alerts in All

WHAT IS IN THE BOX?

(1) X-Series Thermostat Faceplate

(1) WBM-WiFi or WBM-IP Communication Backplate

(2) 3/16 Drywall anchors

(2) Mounting Screws

(1) Installation Manual

COPYRIGHT NOTICE

This manual and its content is a copyright of Network

Thermostat - © Network Thermostat 2020. All rights reserved.
Any redistribution or reproduction of part or all of the contents

in any form is prohibited other than the following:
1. You may print or download for your use only
2. You may not, except with our express written permission,

distribute or commercially exploit the content, nor may you

transmit it or store it in any other website or other form of

electronic retrieval system.

THERMOSTAT CALLOUT

1

Special Status Notifications

2

Secondary Notification Icons

3

Current Equipment Mode Indicators

4

Lock, Override and Hold Icons

5

Current Operation Status Icons

6

Secondary Status Icons

7

Remote Sensor Value (humidity and temperature)

8

Remote Sensor Icons (temperature, indoor, outdoor icons)

9

Occupancy Detection Icon

10

Dot Matrix Display

11

Clock Display

12

Menu Button

13

Mode Button

14

Fan Button

15

Vacation Button

16

Resume/Cancel/Power Button

17

Day of Week Icons

18

Active Schedule Icons

19

Current Temperature Display

20

Up Button (Up Arrow)

21

Down Button (Down Arrow)

22

Back Button (Left Arrow)

23

Accept Button (Right Arrow)

THERMOSTAT LOCATION

To ensure proper operation, the thermostat should be mounted

on an inside wall in a frequently occupied area of the space. In

addition, its position must be at least 18” (46 cm) from any

outside wall, and approximately 5’ (1.5 m) above the floor in a

location with freely circulating air of an average temperature.

Be sure to avoid the following locations:

Behind doors or in corners where freely circulating air is

unavailable

Where direct sunlight or radiant heat from appliances might

affect control operation

On an outside wall

Adjacent to, or in line with, conditioned air discharge grilles,

stairwells or outside doors

Where its operation may be affected by steam or water

pipes or warm air stacks in an adjacent partition, or by any

unheated / uncooled area behind the thermostat

Where operation may be affected by lighting dimmers

Where operation will be affected by the supply air of an

adjacent unit

Near electrical source interference such as arcing relay

contacts

MOUNT THERMOSTAT BACKPLATE

BEFORE YOU BEGIN:

Turn off the power to the HVAC

equipment.

B

TIP:

If you are replacing an existing thermostat, take a

picture of the thermostat wiring for reference.
1. From the factory, the thermostat faceplate is not firmly

connected to the backplate. While holding the thermostat,

firmly near the bottom, gently pull apart the backplate from

the faceplate.

2. Place the rectangular opening in the backplate over the

equipment control wires protruding from the wall. Use the

backplate as a template and mark the location of the two

mounting holes.

A

NOTE:

There are several versions of the X-Series

thermostat. The wiring instructions for the equipment are

identical.

3. Use the supplied anchors and screws for mounting on

drywall or plaster; drill two 3/16” (5mm) diameter holes at

the marked locations; tap the nylon anchors in flush to the

wall surface and fasten backplate using the supplied screws.

C

WARNING:

Do not over tighten the screws!

4. Connect the wires from your system to the thermostat

terminals as shown in the

Wiring Diagrams

section of this

manual. Carefully dress the wires so that any excess is

pushed back into the wall cavity or junction box. Ensure that

the wires are flush to the plastic backplate. The access hole

should be sealed or stuffed to prevent drafts from affecting

the thermostat.

Reattach Faceplate

5. Reattach faceplate to backplate by placing the top of the

faceplate over the top lip of the backplate.

6. Gently swing the thermostat down and press on the bottom

center edge until it snaps in place. This is a tight connection,

but may require a little wiggle to align the pins on the

faceplate with the screw terminals on the backplate before it

snaps into place.

Page 1

240273-03

Отзывы: