NTI RACKMUX KVM Drawer with UNIMUX Switch
22
Figure 24- Master to slave cable connections- multi-user switches
Limitations
¾
All switches used as slaves must have the same number of CPU ports (all 4, 8, or 16 CPU ports).
¾
Up to 8 slaves may be connected to form a maximum system size of 152 ports (1x32 port 8x16 port slaves).
¾
Slaves must be added to the master in order (slave #1 to master’s port 1, slave #2 to master’s port 2, etc).
FYI: Master Port 1 (with an 8-port Slave connected to it) will become ports 1-8 (1-4 for a 4-port slave). Master Unit Port 2
(with a second 8-port Slave Unit connected) will become port numbers 9-16 (5-8 for a 4-port slave).
¾
The front panel buttons (found on most UNIMUX switches) are only used to operate standalone switches. To control a
cascaded network of switches, only the OSD commands within Command Mode will be recognized.
MONITOR 1
MONITOR 2
MONITOR 3
MONITOR 4
USER 1
USER 2
USER 3
USER 4
R
S
2
3
2
NTI
R
CPU 16
MONITOR 1
MONITOR 2
MONITOR 3
MONITOR 4
USER 1
USER 2
USER 3
USER 4
R
S
2
3
2
NTI
R
CPU 16
SLAVE #2 UNIMUX 4X16
SLAVE #1 UNIMUX 4X16
USBVEXT-
xx
-MM
USBVEXT-
xx
-MM
CONNECT MASTER CPU PORT 1
TO ONE USER PORT ON SLAVE1
CONNECT MASTER CPU PORT 2
ONE USER PORT ON SLAVE2
CPU 4
CPU 3
CPU 2
CPU 1
CPU 8
CPU 7
CPU 6
CPU 5
8 4
7 3
6 2
5 1
VIDEO
VIDEO
NETWORK TECHNOLOGIES INC
Tel:330-562-7070
1275 Danner Dr, Aurora, OH 44202
www.nti1.com
Rear View of UNIMUX in RACKMUX-V15-8USB
NTI
Tel:330-562-7070
Fax:330-562-1999
1275 Danner Dr
Aurora, OH 44202
www.nti1.com
R