CWDM-1-8/-9-16/1-8-L/9-16-L/1-8-M/9-16-M  

Rev. 

 

3

 

Connections 

3.1

 

Mounting the CWDM filter 

The CWDM filter must be mounted in a Flashlink subrack. This is done from the rear of the 
subrack. Do not use force when inserting the CWDM filter, once the module’s upper rail 
aligns with the card rail in the subrack, it should slide easily into place. Lock it with 4 
M2.5x8mm screws. 

 

 

Figure 2: CWDM-1-8 mounted in a Flashlink subrack. 

3.2

 

1-8 channel system 

Connect each of the optical ports to the corresponding optical port on the receiver or 
transmitter that matches the signal type and wavelength.  

 

 

Figure 3: Interconnection of an 8 channel system. 

 

 

Figure 4: 8-channel CWDM filter connected to main fibre 

 
 

 

network-electronics.com | 6 

Содержание Flashlink CWDM-1-8

Страница 1: ...network electronics com 8 channel CWDM multiplexer and demultiplexer multi mode M low loss L Rev 2 Flashlink User Manual CWDM 1 8 9 16 CWDM 1 8 M 9 16 M CWDM 1 8 L CWDM 9 16 L...

Страница 2: ...rent revision of this document is the uppermost in the table below Rev Repl Date Sign Change description 2 1 2007 09 01 RS Complete restructuring of user manual adding specifications for L low loss an...

Страница 3: ...CWDM filter 6 3 2 1 8 channel system 6 3 3 9 16 channel system 7 4 Laser safety precautions 8 General environmental requirements for Network Electronics equipment 9 Product Warranty 10 Appendix A Mat...

Страница 4: ...and one from 1270 to 1410nm with an upgrade port By use of the upgrade port up to 16 optical signals can be run over a single fibre The units are passive and all optical devices requiring no power su...

Страница 5: ...max for 16 channels Insertion loss common to upgrade 1dB max single mode Channel Spacing 20nm Passband 13nm min Transmission circuit fibre 9 125um single mode Adjacent Channel Isolation 25dB min Non...

Страница 6: ...r rail aligns with the card rail in the subrack it should slide easily into place Lock it with 4 M2 5x8mm screws Figure 2 CWDM 1 8 mounted in a Flashlink subrack 3 2 1 8 channel system Connect each of...

Страница 7: ...em Using the upgrade port of the CWDM 9 16 enables to have up to 16 wavelengths on a single fibre Each set of 8 channels must first be connected like described in chapter 3 2 figure 3 Figure 5 16 chan...

Страница 8: ...ul when connecting disconnecting fibre pigtails ends Never look directly into the pigtail of the laser fibre Never use microscopes magnifying glasses or eye loupes to look into a fibre end Use laser s...

Страница 9: ...performance specification under the following environmental conditions Operating room temperature range 0 C to 50 C Operating relative humidity range 90 non condensing 2 The equipment will operate wit...

Страница 10: ...rranty terms and conditions for the product s covered by this manual follow the General Sales Conditions by Network Electronics ASA These conditions are available on the company web site of Network El...

Страница 11: ...The guidance on how the EFUP is to be calculated is not finalised at the time of writing See http www aeanet org GovernmentAffairs qfLeOpAaZXaMxqGjSFbEidSdPNtpT pdf for an unofficial translation of th...

Страница 12: ...b site http www network electronics com Please contact Network Electronics Customer Support for assistance with recycling if this site does not show the information you require Where it is not possibl...

Отзывы: