NetWave NWK1 Скачать руководство пользователя страница 5

INS_NWK1_NWK2_QS_REV–   07/7/15   PAGE 5

INSTALLATION REQUIREMENTS

CONFIGURING NETWAVE

QUICK START USER GUIDE 

NWK(1,2)

TECH SUPPORT: 1.888.678.9427

Shielded outdoor CAT 5 or better should be used for all out of plant Ethernet connection and should be properly grounded 
through the PoE AC ground. Industrial grade shielded Ethernet cable is recommended to help prevent ESD damage commonly 
experienced with outdoor installations. Visit www.comnet.net/comnet-products/cables

1.  Connect an Ethernet cable from the port labelled as IN on the power Injection Module to either a laptop or a PC LAN port.

2.  Connect the second Ethernet cable from the OUT port on the Power Injection Module to the NetWave LAN port. 

3.  Apply 48 VDC to the Power Injection Module with the provided power supply. You should notice the green LED illuminate in 

the Power Injection Module and the power LED on the NetWave unit.

4.  Set the IP address of the laptop being used to configure NetWave to static and the subnet to 192.168.10.x/24 subnet.

5.  Point the Browser to 192.168.10.100 for the Access Point or 192.168.10.101 for the Client. These are the default addresses.

6.  A login prompt will pop up. Enter: 

ID: 

admin

 

 

Password: 

admin

7.  Select the NETWORK 

»

 Interfaces tab, click on Edit in the LAN settings section to change the IP address of the device. and set 

the desired network settings. 
• Hit Save & Apply 
NOTE:  This will be the network address for the NetWave web server. It is not necessary to set to the same subnet as the 

operating network but it is recommended.

8.  Select the NETWORK -> WIFI tab and set: 

• Wireless mode – Set to AP or Client 
• Country code – Only required if setting up the NW2 and NWK2 (ETSI) models 
NOTE:  It is the user’s responsibility to ensure that the correct country is chosen. ComNet accepts no liability for incorrectly set 

up equipment. 

• Output RF power – if RSSI is greater than -40, it is recommended to reduce RF TX power at the connected remote node.

• Set SSID – if changing from the default setting

•  Channel Spectrum Width – May want to reduce to 20M from the default 20/40M if the 5GHz spectrum is crowded or 

connections across the link are unstable.

• Wireless Security – if changing from default settings

• Hit Save & Apply

Содержание NWK1

Страница 1: ...strial Point to Point Kit FCC Version Includes NWK1_AP and NWK1_CL NWK2 Industrial Point to Point Kit ETSI Version Includes NWK2_AP and NWK2_CL An easy to read LED array displays unit operational stat...

Страница 2: ...the unit is in reset LAN SOLID GREEN LAN Connected OFF No Connectivity RSSI1 SOLID RED Weak Connection RSSI2 SOLID ORANGE Moderate Connection RSSI3 SOLID GREEN Solid Connection RSSI4 SOLID GREEN Excel...

Страница 3: ...be used Once the cable has been routed through the weather connection as shown above push the split rubber gasket into place and loosely screw the cap that goes over the rubber washer B Snap the RJ 4...

Страница 4: ..._NWK1_NWK2_QS_REV 07 7 15 PAGE 4 QUICK START USER GUIDE NWK 1 2 TECH SUPPORT 1 888 678 9427 Included Hardware Vertical Mount in 45 Position Vertical Mount in 45 Position FIGURE 4 POLE MOUNT INSTRUCTIO...

Страница 5: ...10 x 24 subnet 5 Point the Browser to 192 168 10 100 for the Access Point or 192 168 10 101 for the Client These are the default addresses 6 A login prompt will pop up Enter ID admin Password admin 7...

Страница 6: ...RENGTH The Received Signal Strength Indicator RSSI is intended to be used as an indicator of the quality of connection that exists between an Access Point and Client radio The RSSI value is determined...

Страница 7: ...mNet Gigabit Managed Switch with 30W PoE NWK1_AP PoE QUICK START USER GUIDE NWK 1 2 Power NWK1_CL NWK1_AP POINT TO POINT TOPOLOGY UTILIZING DUAL PORTS ComNet Managed Switch with 30 W PoE Connected to...

Страница 8: ...ui est n cessaire pour une communication r ussie Cet appareil est conforme la norme RSS Industrie Canada exempts de licence norme s Son fonctionnement est soumis aux deux conditions suivantes 17 Compl...

Страница 9: ...44 0 113 253 7462 INFO EUROPE COMNET NET Need Additional Assistance Visit our website http www comnet net or contact Comnet tech support Tel 203 796 5300 Toll free 888 678 9427 Email techsupport comn...

Отзывы: