Page 30/ 191
2.10 Cable recommendation
To provide optimal shielding maritime CAT.7 S/FTP 23 AWG LSFROH SHF1 is preferred which
is specifically suited for installation on board ships and sea movable constructions, has a high
shielding performance and can withstand harsh environments.
Cable length max. 100m* unless otherwise specified in cable diagram.
Cable screen must be grounded unless otherwise specified on connection diagram.
*Length is measured from cable entrance/socket to cable entrance/socket.
All equipment to be grounded with 6mm
2
wire unless otherwise specified.
Core Identification:
For compatibility with above cable types following applies:
BU - blue
NC - neutral color: white or black or transparent
If applicable, only for FMKHC 2x2x0.75 use conversion table:
1BU - BK
1NC - BN
2BU - BU
2NC - GY