background image

 

 

4.Set up Instruction 

On/Off 

 

Power on 

Open the upper cover and insert 2 AAA 1.5V batteries   

(You may use tools to open the upper cover, such as a screwdriver) 

Turn on   

Press the function key till seeing one green indicator flash and one red indicator flash.   

Turn off   

(Restore to factory setting) 

Press and hold the function key for 5 seconds till green indicator light flashes for 20 times. 

Power off 

Remove Batteries.   

Note 

1.

 

The device will be off after removing the battery and insert it again. 

2.

 

It is suggested to wait for at least 10 seconds between turning the device on and off. 

3.

 

To enter the engineering test mode: keep pressing the function key and then insert the batteries   

Network Joining

 

 

If the device has never joined 

the network 

Turn on the device, and it will search for the network to join. 

The green indicator light stays on for 5 seconds: joins the network successfully 

The green indicator light remains off: fail to join the network 

If the device has joined the 

network and it is not set to 

default 

Turn on the device, and it will search for the previous network to join. 

The green indicator light stays on for 5 seconds: joins the network successfully 

The green indicator light remains off: fail to join the network 

If the device fails to join the 

network   

(when the device is turned 

on) 

For the first two minutes: the device will wake up every 15 seconds to send a join request. 

After two minutes: the device will enter sleep mode and wake up every 15 minutes to send a join 

request. 

Note: It is suggested to remove the batteries if the device is not in use to save power.   

     It is suggested to check the device verification information on the gateway   

     or consult your platform server provider when the device fails to join the network. 

Function Key

 

 

Press the function key and 

hold the pressing for 5 

seconds 

The device will be set to default and turned off 

The green indicator light flashes for 20 times: success 

The green indicator light remains off: fail 

Press the function key once   

The device is in the network: green indicator light flashes once and sends a report 

The device is not in the network: green indicator light remains off 

Press the emergency button 

The device is in the network: red indicator light flashes once and sends an alarm report 

The device is not in the network: red indicator light remains off 

Note: The report interval can be adjusted; please refer to the command 

ConfigButtonPressTime 

 

Содержание RB02I

Страница 1: ...o Ltd This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties in whole or in part without written permission of NETVOX Technology The specifications are subject to change without prior notice ...

Страница 2: ...1 Table of Content 1 Introduction 2 2 Appearance 2 3 Main Features 3 4 Set up Instruction 4 5 Data Report 6 6 Installation 10 7 Important Maintenance Instruction 11 ...

Страница 3: ...d spectrum modulation technique greatly extend the communication distance It can be widely used in any use case that requires long distance and low data wireless communications For example automatic meter reading building automation equipment wireless security systems industrial monitoring It has features like small size low power consumption long transmission distance strong anti interference abi...

Страница 4: ...n be set via SMS text and email optional Applicable to third party platforms Actility ThingPark TTN MyDevices Cayenne Improved power management for longer battery life Battery Life Please refer to web http www netvox com tw electric electric_calc html At this web page users can find battery life calculation for variety models at different configurations Kindly note the actual battery life is deter...

Страница 5: ...ight stays on for 5 seconds joins the network successfully The green indicator light remains off fail to join the network If the device fails to join the network when the device is turned on For the first two minutes the device will wake up every 15 seconds to send a join request After two minutes the device will enter sleep mode and wake up every 15 minutes to send a join request Note It is sugge...

Страница 6: ... report according to Min Interval The device is turned on but not in the network First two mins wake up every 15 seconds to send request After two mins enter sleeping mode and wake up every 15 minutes to send request Note Suggest to remove batteries if the device is not used Suggest to check device verification on gateway Low Voltage Warning Low Voltage 2 1V ...

Страница 7: ...cket report along with an uplink packet including alarm status and battery voltage when it joins the network The device sends data with default configurations before any new configuration is done Default setting MaxTime Max Interval 60 min 3600s MinTime Min Interval 60 min 3600s BatteryChange 0x01 0 1V Emergency alarm When emergency button is pressed that report 1 When emergency button is not pres...

Страница 8: ...Rsp 0x81 Status 0x00_success Reserved 8Bytes Fixed 0x00 ReadConfig ReportReq 0x02 Reserved 9Bytes Fixed 0x00 ReadConfig ReportRsp 0x82 MinTime 2bytes Unit s MaxTime 2bytes Unit s BatteryChange 1byte Unit 0 1v Reserved 4Bytes Fixed 0x00 1 Configure device parameters MinTime 1min MaxTime 1min BatteryChange 0 1v Downlink 0110003C003C0100000000 Device returns 8110000000000000000000 configuration is su...

Страница 9: ...h and so on SetButtonPressTimeRsp 0x81 Status 0x00_Success 0x01_Failure GetButtonPressTimeReq 0x02 GetButtonPressTimeRsp 0x82 PressTime 1bytes OtherValue present the press time such as 0x01_1 Second push 0x02_2 Seconds push 0x03_3 Seconds push 0x04_4 Seconds push 0x05_5 Seconds push and so on 3 Setting ButtonPressTime as 10 seconds to alarm Downlink 010A Device returns 8100 configuration successfu...

Страница 10: ...ter than the last data reported the device reports according to MaxTime interval 3 We do not recommend to set the MinTime Interval value too low If the MinTime Interval is too low the device wakes up frequently and the battery will be drained soon 4 Whenever the device sends a report no matter resulting from data variation button pushed or MaxTime interval another cycle of MinTime MaxTime calculat...

Страница 11: ...o below Please keep the device from metals or other electronics so the transmission of the device will not be affected Applicable use cases for RB02I wireless emergency push button include but are not limited to the following Home bathrooms Schools Nursing homes Hospitals Banks Hotels 2 Insert the batteries in the battery holder and put the upper cover back Put on the included waterproof silicone ...

Страница 12: ...melt some plastic parts Do not store the device in places that are too cold Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not throw knock or shake the device Rough handling of equipment can destroy internal circuit boards and delicate structures Do not clean the device with strong chemicals detergents or strong detergents Do no...