ReportMinTime: 50s;
ReportChange: 0;

Note: ReportMaxTime time can be programmed by CustomData with NLPP, specifying the default
value of the factory ReportMaxTime (default factory setting is: 140min =8400s).

The RA0716A16A device does not support the ReportChange function, that is, the configuration is
invalid. The sent report data string is always sent according to the ReportMaxTime cycle. The
ReportMinTime are 50 seconds which is fixed. It does not support to send report according to
ReportMinTime.

Note:
1. The value of ReportMaxTime are greater than 60 seconds.
2. Since the dust sensor works stably, it requires about 45 seconds after powering on to send report
data.
3. The RA0716A device also supports Cayenne's TxPeriod cycle configuration instructions.
Therefore, RA0716A can also perform the report according to the cycle time of the TxPeriod value;
and at a certain time, the report period is ReportMaxTime or TxPeriod, depending on which cycle
time is configured last time.
4. After pressing the button, the device needs to warm up and process the sensor information for a
while, please be patient.

5. Restore to Factory Setting

RA0716A has a power-down save network information memory function. This feature is turned off
by default. That is, it will be re-joined to the network every time when it is powered back on.
To enable it by using the ResumeNetOnOff command, each time the power is rewritten, the last
joining information will be recorded (including saving the network address information assigned to
it, etc., if users want to join a new network, you need to perform a factory reset first. The set
operation) will not be re-joined.
Operation method:
1. Press and hold the binding button for 5 seconds to release (the binding button is released when the
LED flashes), and the LED flashes 20 times;
2. RA0716A automatically restarts to start re-joining to the network.
Note: Restore factory settings, ACK is off by default; ADR is enabled by default.

6. Installation

This product does not have a waterproof function. After the network joining is completed, please
place it indoor.
PM 2.5 sensor has an average time between failures of 3 years, a concentration of more than 300