background image

 

 

5. Data Report 

 

     

  After power on, the device will immediately send a version packet report and the data report including the temperature, 

humidity, PM2.5 and voltage. 

The device sends data according to the default configuration before any other configuring. 

ReportMaxTime: 900s 

                           

* MaxTime 

cannot

 be set less than 15 min   

                           

* The value of the ReportMaxTime should be greater than ReportType count 

x

 Report10 

ReportMinTime: 30s

   

                                 

  120s (EU868)

 

The MinTime configuration is not available. But the software has restriction, MinTime must be configured a 

number greater than 0. ) 

ReportType count = 1 

Note: 

(1) The cycle of the device sending the data report is according to the default. 

(2) The interval between two reports must be the MaxTime. 

(3) ReportChange is not supported by RA0716 (Invalid configuration). The data report is sent 

    according to ReportMaxTime as a cycle (the first data report is the start to the end of a cycle). 

(4) Data pocket: PM2.5, voltage, temperature and humidity. 

(5) The device also supports the TxPeriod cycle configuration instructions of Cayenne. Therefore, the device can   

perform the report according to the TxPeriod cycle. The particular report cycle is ReportMaxTime or TxPeriod 

depending on which report cycle was configured last time. 

(6) It would take 

35 seconds

 for the sensor to sample and process the collected value after pressing the button,   

please be patient. 

 

The device reported data parsing please refer to 

Netvox LoraWAN Application Command document

 and 

Netvox Lora 

Command Resolver

 

http://loraresolver.netvoxcloud.com:8888/page/index

 

 

 

 

 

 

 

 

Содержание RA0716

Страница 1: ...opyright Netvox Technology Co Ltd This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be discl...

Страница 2: ...1 Table of Content 1 Introduction 2 2 Appearance 3 3 Main Feature 3 4 Set up Instruction 3 5 Data Report 5 6 Installation 7 7 Important Maintenance Instruction 8...

Страница 3: ...nsumption Compared with other communication methods LoRa spread spectrum modulation method greatly increases to expand the communication distance Widely used in long distance low data wireless communi...

Страница 4: ...Off Power On RA0716 is connected to DC 12V adapter for power on Turn On Connect with power on to turn on Restore to Factory Setting Press and hold the function key for 5 seconds and the green indicat...

Страница 5: ...tor flashes once and the device sends a data report The device is not in the network the green indicator remains off Threshold Restore to Factory Setting Description RA0716 has the function of the pow...

Страница 6: ...interval between two reports must be the MaxTime 3 ReportChange is not supported by RA0716 Invalid configuration The data report is sent according to ReportMaxTime as a cycle the first data report is...

Страница 7: ...value of MaxTime should be 900s 2 Read RA0716 device parameter Downlink 0235000000000000000000 Device Return 8235001E03840000000000 device current parameter Description Device CmdI D DeviceType Netvox...

Страница 8: ...A0716 periodically reports the data including the temperature humidity and PM2 5 according to ReportMaxTime The default MaxTime is 900 seconds Note MaxTime can be modified through the downlink command...

Страница 9: ...batteries and deform or melt some plastic parts Do not store in excessive cold place Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board...

Отзывы: