5
The R727 device does not support the ReportChange function. That is, the configuration is
invalid, and the sent report data string is always sent according to the ReportMaxTime. The
ReportMinTime is the R727 device's sending interval of the report data string (since the R727
device needs to send multiple data strings at one time. So it is designed to use ReportMinTime
to do separate the multiple data stings).
R727 data types for each series of Reports:
R72701: The Report data of the device is: CO gas, ReportType count = 1;
R72711: The data of this device Report is: the height of the liquid, ReportType count = 1;
R72713: The Report data of the device is: soil temperature, soil moisture and soil conductivity,
ReportType count = 1;
R72715: The report data of the device is: air temperature and humidity and CO2 (MH-14),
ReportType count = 2;
R72716: The Report data of the device is: air temperature and humidity and dust (PM2.5),
ReportType count = 1 (integrated into one);
R72723: The Report data of the device is: air temperature and humidity, dust (PM2.5) and noise,
ReportType count = 3;
R72724: The Report data of the device is: air temperature, humidity and noise, ReportType
count = 2;
Note:
1.ReportMaxTime value must be greater than (ReportType count *Report10 units:
seconds);
2. Since the dust sensor/CO2 (MH-14) is stable and requires about 60 seconds after power-on,
the devices which carries dust sensor/CO2 (MH-14) is not reported until 60 seconds.
The R727 device also supports the Cayenne TxPeriod cycle configuration command. Therefore,
the R727 can also perform the report according to the cycle time of the TxPeriod value. At a
specific time, the report period is ReportMaxTime or TxPeriod, depending on which cycle time
is last configured.
5. Restore to Factory Setting
R727 saves data including network key information, configuration information, etc. To restore to
factory setting, users need to execute below operations.
The R727 has a function to save and save the network information and memory. This function is
setted to be off by default, that is, it will be re-joined every time you turn on the power again. This
function can be turned on through the ResumeNetOnOff command, then each time users power on
the device, it will record the last network information (including saving its assigned network address
information, etc., to join a new network, you need to perform a restoration of the factory setting)
which will not be re-joined to network.