4
3. Main Features
Compatible with LoRaWAN
DC 12V adapter powered
Easy set up and installation
4.Set up Instruction
4.1 Join Into Lora Network
The R727 is powered by 12V DC and can communicate with the gateway. Users will firstly add
R727 to the gateway's network.
Operations to join the network:
(1) After the device is powered on, the device which never be joined into the network will
automatically scan a new network to join. After joining to the available network, the green indicator
will light up for 5 seconds and the device will be successfully added. Otherwise, the indicator light
will not work.
(2) For devices that have been added to the network, the green indicator light is on for 5s after the
power is turned off and turned on, indicating that it is already in the network.
4.2 Function Key
(1) Press and hold both function keys for 5 seconds to reset to factory setting. After restoring to
factory setting successfully, the green indicator will flashes quickly 20 times.
(2)
Press any function key to turn on the device; the green indicator flashes once and it will send a
data report.
4.3 Data Report
After the device is powered on, a version package will be sent immediately. The R727 device
will send a power report (PM value and air temperature and humidity value) after about 10
seconds after power-on.
The default report configuration of the device is as follows:
ReportMaxTime: 180s;
ReportMinTime: 30s;
ReportChange: 0;
Note: The ReportMaxTime time can be programmed by NLPP CustomData, specify the default
value of the factory ReportMaxTime (default factory setting is 3min = 180s).