5
5. Data Report
After power on, the device will immediately send a version packet report and a data report including
the device battery voltage, the
number and status of toilet water tank replenishment.
Default setting:
Max Interval = 0x0E10 (3600s)
Min Interval = 0x0E10 (3600s) // Every Min Interval will detect the current voltage one time
Battery Change = 0x01 (0.1v)
DailyReplenishwaterAlarmcount = 0x0032 (50 times)
FalutCheckTime = 0x012C (300s)
* If there is a special customized order, the setting of the device will change according to customer’s requirements
Fault Alarm:
FaultAlarm is reported as 0, indicating that the single water supplement of the toilet water tank is normal.
FaultAlarm
is reported as 1, indicating that the single water supplement of the toilet water tank is abnormal.
Tank Leak Alarm:
TankLeakAlarm is reported as 0, indicating that the number of water replenishments in the toilet water tank within 24 hours is
normal.
TankLeakAlarm is reported as 1, indicating that the number of water replenishments in the toilet water tank within 24 hours is
abnormal.
Replenish water count:
Replenishwatercount is the cumulative make-up times of the toilet water tank.
When the device is powered off, clear or issue a command to clear (ClearReplenishwatercountReq).
Note:
1. The cycle of the device sending the data report is according to the default.
2. The interval between two reports must be the MinTime.
The device reported data parsing please refer to Netvox LoRaWAN Application Command document and Netvox Lora Command
Resolver
http://loraresolver.netvoxcloud.com:8888/page/index
Data report configuration and sending period are as following:
Min Interval
(Unit: second)
Max Interval
(Unit: second)
Reportable Change
Current Change
≥
Reportable Change
Current Change<
Reportable Change
Any number between
1~65535
Any number between
1~65535
Can not be 0
Report
per Min Interval
Report
per Max Interval
5.1 Example of ReportDataCmd
FPort
:
0x06
Bytes
1
1
1
Var(Fix=8 Bytes)
Version
DeviceType
ReportType
NetvoxPayLoadData
Version
– 1 byte –0x01
——
the Version of NetvoxLoRaWAN Application Command Version
DeviceType
– 1 byte – Device Type of Device
The devicetype is listed in Netvox LoRaWAN Application Devicetype doc