7. Important Maintenance Instruction 

Kindly pay attention to the following in order to achieve the best maintenance of the product: 

 

• Keep the device dry. Rain, moisture and various liquids or water may contain minerals that can corrode electronic circuits. In case the 

device is wet, please dry it completely. 

• Do not use or store in dusty or dirty areas. This way can damage its detachable parts and electronic components. 

• Do not store in excessive heat place. High temperatures can shorten the life of electronic devices, destroy batteries, and deform or 

melt some plastic parts. 

• Do not store in excessive cold place. Otherwise, when the temperature rises to normal temperature, moisture will form inside which 

will destroy the board. 

• Do not throw, knock or shake the device. Treating device roughly can destroy internal circuit boards and delicate structures. 

• Do not wash with strong chemicals, detergents or strong detergents. 

• Do not paint the device. Smudges can make debris block detachable parts up and affect normal operation. 

• Do not throw the battery into the fire to prevent the battery from exploding. Damaged batteries may also explode. 

 

All the above suggestions apply equally to your device, batteries and accessories.   

If any device is not operating properly, please take it to the nearest authorized service facility for repairing. 

Содержание R718UBD Series

Страница 1: ...chnology Co Ltd This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other part...

Страница 2: ...Report 6 5 1 Example of ReportDataCmd 7 5 2 Example of ConfigureCmd 8 5 3 Example of calibration configuration 10 6 Installation 12 6 1 Precautions for use of dust sensor 12 6 2 Precautions for use of...

Страница 3: ...wer consumption Compared with other communication methods LoRa spread spectrum modulation method greatly increases to expand the communication distance Widely used in long distance low data wireless c...

Страница 4: ...light R718UBD235 CO2 vibration air pressure light R718UBD1235 CO2 temperature and humidity vibration air pressure light R718UBD126 CO2 temperature and humidity vibration TVOC R718UBD1236 CO2 temperat...

Страница 5: ...rbed on iron objects Host Body Protection Level IP65 Compatible with LoRaWANTM Class A Frequency Hopping Spread Spectrum FHSS technology Configuration parameters can be configured through third party...

Страница 6: ...work not at factory setting Turn on the device to search the previous network to join The green indicator stays on for 5 seconds success The green indicator remains off fail Fail to Join The Network S...

Страница 7: ...g data information Note The interval between multiple data packets is mintime Note 1 Before any configuration the device sends data according to the default configuration 2 Do not send any configurati...

Страница 8: ...ShockEvent 1Byte 0x00_NoShock 0x01_ Shock 0x02 Battery 1Byte unit 0 1V AirPressure 4Bytes unit 0 01hPa illuminance 3Bytes unit 1Lux 0x03 Battery 1Byte unit 0 1V PM2 5 2Bytes Unit 1 ug m3 PM10 2Bytes U...

Страница 9: ...11 HEX 17 DEC 9th 10th byte FFFF TVOC 11th byte 00 Reserved Note Unsupported sensor detection item data is 0xFF 0xFFFF 0xFFFFFF 0xFFFFFFFF 5 2 Example of ConfigureCmd FPort 0x07 Bytes 1 1 Var Fix 9 By...

Страница 10: ...Configure the device parameter MinTime 300s MaxTime 900s Downlink 01BB012C03840000000000 12C Hex 300 Dec 384 Hex 900 Dec Device return 81BB000000000000000000 configuration successful 81BB0100000000000...

Страница 11: ...device current parameter 5 GetShockSensorSensitivityReq Downlink 05BB000000000000000000 Device return 85BB0A0000000000000000 device current parameter 5 3 Example of calibration configuration FPort 0x0...

Страница 12: ...0106000001000100640000 Device return 8106000000000000000000 configuration successful 8106000100000000000000 configuration failed 2 GetGlobalCalibrateReq Downlink 0206000000000000000000 Device return...

Страница 13: ...s tens of thousands of ppm when liquid ammonia or alcohol volatilizes and the carbon dioxide concentration in human breath can be as high as 40000 ppm which will damage the sensor After being used for...

Страница 14: ...internal electronic function is normal IP65 dust proof and to prevent damage caused by water from nozzles in all directions from invading electrical appliances It can be used in general indoor enviro...

Страница 15: ...astic parts Do not store in excessive cold place Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not throw knock or shake the devic...