4. Set up Instruction 

On/Off 

 

Power on 

Insert batteries. (users may need a screwdriver to open) 

Turn on   

Press and hold the function key for 3 seconds till the green indicator flashes once.   

Turn off   

(Restore to factory setting) 

Press and hold the function key for 5 seconds till green indicator flashes for 20 

times. 

Power off 

Remove Batteries.   

Note 

1.

 

Remove and insert the battery; the device is at off state by default. 

2.

 

On/off interval is suggested to be about 10 seconds to avoid the interference of   

capacitor inductance and other energy storage components. 

3. At 1

st

 -5

th

 second after power on, the device will be in engineering test mode.   

Network Joining

 

 

Never joined the network 

Turn on the device to search the network to join. 

The green indicator stays on for 5 seconds: success 

The green indicator remains off: fail 

Had joined the network 

(not at factory setting) 

Turn on the device to search the previous network to join. 

The green indicator stays on for 5 seconds: success 

The green indicator remains off: fail 

Function Key

 

 

Press and hold for 5 seconds 

Restore to factory setting / Turn off 

The green indicator flashes for 20 times: success 

The green indicator remains off: fail 

Press once   

The device is in the network: green indicator flashes once and sends a report 

The device is not in the network: green indicator remains off 

Sleeping Mode

 

 

The device is on and in the 

network 

Sleeping period: Min Interval. 

When the reportchange exceeds setting value or the state changes: send a data report 

according to Min Interval.   

Содержание R718PG

Страница 1: ...s document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties in whole or in...

Страница 2: ...able of Content 1 Introduction 2 2 Appearance 2 3 Main Features 3 4 Set up Instruction 4 5 Data Report 5 6 Installation 9 7 Information about Battery Passivation 10 8 Important Maintenance Instruction...

Страница 3: ...spread spectrum modulation method greatly increases to expand the communication distance Widely used in long distance low data wireless communications For example automatic meter reading building auto...

Страница 4: ...can be read and alerts can be set via SMS text and email optional Applicable to third party platforms Actility ThingPark TTN MyDevices Cayenne Improved power management for longer battery life Battery...

Страница 5: ...joined the network Turn on the device to search the network to join The green indicator stays on for 5 seconds success The green indicator remains off fail Had joined the network not at factory setti...

Страница 6: ...uplink packet including illuminance and battery voltage The device sends data in the default configuration before any configuration is done Default setting MaxTime Max Interval 15 min 900s MinTime Min...

Страница 7: ...tRsp 0x81 Status 0x00_success Reserved 8Bytes Fixed 0x00 ReadConfig ReportReq 0x02 Reserved 9Bytes Fixed 0x00 ReadConfig ReportRsp 0x82 MinTime 2bytes Unit s MaxTime 2bytes Unit s BatteryChange 1byte...

Страница 8: ...sleeping 0H 15th M 30th M 45th M 1H 2H Example 3 based on MinTime 15 Minutes MaxTime 1 Hour Reportable Change i e BatteryVoltageChange 0 1V MaxTime Wakes up and collects data 3 6V Does not report Wake...

Страница 9: ...than the last data reported the device reports according to MaxTime interval 3 We do not recommend to set the MinTime Interval value too low If the MinTime Interval is too low the device wakes up freq...

Страница 10: ...ollowing scenarios Family School Storage room Hospital Bar Stairs Agricultural greenhouse To detect the illumination value 1 Light Sensor R718PG has a built in magnet see Figure 1 below When installed...

Страница 11: ...tery passivation may also lead to voltage delay when the batteries are put into operation and our devices may not work correctly in this situation As a result please make sure to source batteries from...

Страница 12: ...elt some plastic parts Do not store the device in places that are too cold Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not thro...

Отзывы: