4.Set up Instruction 

On/Off 

 

Power on 

Insert batteries. (users may need a screwdriver to open the battery cover) 

Turn on   

Press and hold the function key for 3 seconds till the green indicator flashes once.   

Turn off (Restore to factory setting) 

Press and hold the function key for 5 seconds till green indicator flashes 20 times. 

Power off 

Remove Batteries.   

Note 

1.The device will be off in default after removing the battery and insert it again. 

2.It is suggested to wait for at least 10 seconds between turning the device on and off. 

3.At 1

st

 -5

th

 second after power on, the device will be in engineering test mode.   

Network Joining

 

 

Never joined the network 

Turn on the device, and it will search for the network to join. 

The green indicator light stays on for 5 seconds: joins the network successfully 

The green indicator light remains off: fail to join the network 

Had joined the network 

(not restore to factory setting) 

Turn on the device, and it will search for the previous network to join. 

The green indicator light stays on for 5 seconds: joins the network successfully 

The green indicator light remains off: fail to join the network 

Fail to Join the Network 

1.

 

Suggest to remove batteries if the device is not used to save power.   

2.

 

Suggest to check the device verification information on the gateway or consult your 

platform server provider. 

Function Key

 

 

Press the function key and hold the 

pressing for 5 seconds 

The device will be set to default and turned off 

The green indicator light flashes 20 times: success 

The green indicator light remains off: fail 

Press the function key once   

The device is in the network: green indicator light flashes once and sends a report 

The device is not in the network: green indicator light remains off 

Sleeping Mode

 

 

The device is turned on and in the 

network 

Sleep period: Min Interval. 

When the reportchange exceeds setting value or the state changes: send a data report 

according to Min Interval.   

The device is on but not in   

the network 

1.

 

Suggest to remove batteries if the device is not used.   

2.

 

Suggest to check device verification on gateway. 

Low Voltage Warning 

Low Voltage 

3.2V 

Содержание R718N3

Страница 1: ...td This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties in whole...

Страница 2: ...3 Main Features 3 4 Set up Instruction 4 5 Data Report 5 6 Installation 9 7 Information about Battery Passivation 12 7 1 To determine whether a battery requires activation 12 7 2 How to activate the...

Страница 3: ...T Range 150A 3000A 1 When the current of the device that is 75A or below is less than 100mA the current is reported as 0 When the current of the device that is above 75A is less than 1A the current is...

Страница 4: ...ess sensor monitoring and notification system to configure sensors view data and set alerts via SMS text and email optional Available third party platform Actility ThingPark TTN MyDevices Cayenne Low...

Страница 5: ...the previous network to join The green indicator light stays on for 5 seconds joins the network successfully The green indicator light remains off fail to join the network Fail to Join the Network 1 S...

Страница 6: ...ny configuration is done Default setting Maximum time Max Interval 15 min 900 s Minimum time Min Interval 15 min 900 s CurrentChange 0x0064 100 mA The interval between min time and max time must be th...

Страница 7: ...1 Status 0x00_success Reserved 8Bytes Fixed 0x00 ReadConfig ReportReq 0x02 Reserved 9Bytes Fixed 0x00 ReadConfig ReportRsp 0x82 MinTime 2bytes Unit s MaxTime 2bytes Unit s CurrentChange 2byte Unit 1mA...

Страница 8: ...iplier 3 7000 10 70000 mA 70A Example for MinTime MaxTime logic Example 1 based on MinTime 1 Hour MaxTime 1 Hour Reportable Change i e BatteryVoltageChange 0 1V MaxTime MaxTime Sleeping MinTime Sleepi...

Страница 9: ...recommend to set the MinTime Interval value too low If the MinTime Interval is too low the device wakes up frequently and the battery will be drained soon 4 Whenever the device sends a report no matte...

Страница 10: ...ta will be reported regularly according to MaxTime 5 Press the Key of the device to start sampling data and report the data after 3 to 5 seconds Note MaxTime must be set greater than Min Time The thre...

Страница 11: ...t transformer and start the measurement according to the wiring below CT Wiring Schematic Diagram Current direction K L Installation Diagram Screw Fixation Screw Fixation R718N3 Wire to be detected Wi...

Страница 12: ...ssemble the device unless it is required to replace the batteries Do not touch the waterproof gasket LED indicator light function keys when replacing the batteries Please use suitable screwdriver to t...

Страница 13: ...orage period is more than one month from the date of battery production all the batteries should be activated If encountering the situation of battery passivation users can activate the battery to eli...

Страница 14: ...melt some plastic parts Do not store the device in places that are too cold Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not thr...

Отзывы: