background image

 

 

12 

Note: 

Please do not disassemble the device unless it is required to replace the batteries.   

Do not touch the waterproof gasket, LED indicator light, function keys when replacing the batteries. Please use suitable screwdriver to 

tighten the screws (if using an electric screwdriver, it is recommended to set the torque as 4kgf) to ensure the device is impermeable. 

 

8. Information about Battery Passivation 

 

Many of Netvox devices are powered by 3.6V ER14505 Li-SOCl2 (lithium-thionyl chloride) batteries that offer many advantages 

including low self-discharge rate and high energy density.    

 

However, primary lithium batteries like Li-SOCl2 batteries will form a passivation layer as a reaction between the lithium anode and 

thionyl chloride if they are in storage for a long time or if the storage temperature is too high. This lithium chloride layer prevents rapid 

self-discharge caused by continuous reaction between lithium and thionyl chloride, but battery passivation may also lead to voltage 

delay when the batteries are put into operation, and our devices may not work correctly in this situation.    

 

As a result, please make sure to source batteries from reliable vendors, and the batteries should be produced within the last three 

months.      

 

If encountering the situation of battery passivation, users can activate the battery to eliminate the battery hysteresis. 

 

 

*To determine whether a battery requires activation 

Connect a new ER14505 battery to a 68ohm resistor in parallel, and check the voltage of the circuit. 

If the voltage is below 3.3V, it means the battery requires activation. 

 

*How to activate the battery 

1) Connect a battery to a 68ohm resistor in parallel 

2) Keep the connection for 6~8 minutes 

3) The voltage of the circuit should be 

3.3V 

 

 

 

 

 

 

 

 

 

 

Содержание R718N1

Страница 1: ...o Ltd This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties in who...

Страница 2: ...Introduction 2 2 Appearance 3 3 Main Features 3 4 Set up Instruction 4 5 Data Report 5 6 Measuring Range and Accuracy 9 7 Installation 10 8 Information about Battery Passivation 12 9 Important Mainte...

Страница 3: ...Meter with 1 x630A CT Split core They are compatible with LoRaWAN protocol LoRa Wireless Technology LoRa is a wireless communication technology dedicated to long distance and low power consumption Co...

Страница 4: ...h third party software platforms data can be read and alarms can be set via SMS text and email optional Available third party platform Actility ThingPark TTN MyDevices Cayenne Low power consumption an...

Страница 5: ...etwork Turn on the device to search the network to join The green indicator stays on for 5 seconds success The green indicator remains off fail Had joined the network not at factory setting Turn on th...

Страница 6: ...Min Interval 30 min 1800s Check the current voltage once per Min Interval CurrentChange 0x0064 100mA Note The data transmission period of the device is subject to the programming configuration If the...

Страница 7: ...etvoxPayLoadData Fixed bytes Fixed 8bytes Version Device Type Report Type NetvoxPayLoadData 0x01 0x49 0x01 Battery 1Byte unit 0 1V Current 2Bytes Unit 1ma Multiplier 1Byte the real current should conv...

Страница 8: ...ort Rsp 0x81 Status 0x00_success Reserved 8Bytes Fixed 0x00 ReadConfig ReportReq 0x02 Reserved 9Bytes Fixed 0x00 ReadConfig ReportRsp 0x82 MinTime 2bytes Unit s MaxTime 2bytes Unit s CurrentChange 2by...

Страница 9: ...ce reports according to MaxTime interval 3 We do not recommend to set the MinTime Interval value too low If the MinTime Interval is too low the device wakes up frequently and the battery will be drain...

Страница 10: ...range is 100mA 75A 1 718R718N115 split CT Measurement range is 1A 150A 1 718R718N125 split CT Measurement range is 1A 250A 1 718R718N163 split CT The measurement range is 5A 630A 1 Note The three larg...

Страница 11: ...ixed to the wall with screws When installing the current transformer separate the live and neutral wires and take out the live wire separately and start the measurement according to the wiring below C...

Страница 12: ...dden to use in humid and corrosive gas environments Before installation please confirm the current value of the load If the current value of the load is higher than the measurement range select a mode...

Страница 13: ...me or if the storage temperature is too high This lithium chloride layer prevents rapid self discharge caused by continuous reaction between lithium and thionyl chloride but battery passivation may al...

Страница 14: ...elt some plastic parts Do not store the device in places that are too cold Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not thro...

Отзывы: