10
6. Installation
This device has a waterproof function. When the device is used, the back of it can be attached to the
iron surface, or two ends of it
can be secured on the wall by screws.
When the magnet is close to or far away, the sensor will be triggered to send a report.
The gap between the Hall sensor and the magnet should be less than
3cm
during installation.
When the installation clearance is greater than 3cm, the device will not be able to trigger the signal.
1.
The Wireless 2-gang Hall Type Open/Close
Detection Sensor (R718LB2) has a built-in
magnet (see Figure 1 below).
It can be attached to the surface with iron material
during installation.
To make the installation more secure, please use
screws (purchased separately) to fix the device on
the wall or other objects (see Figure 2 below).
Comment:
Do not install the device in a metal shielded box or
in an environment surrounded by other electrical
equipment to avoid affecting the wireless
transmission of the device.
Figure 1
Figure 1
Figure 2
2. Tear off 3M release paper of Hall sensor and
the magnet then attach to the door or window
in parallel.
Note: The mounting distance between the Hall
sensor and the magnet should be less
than 3cm.
3. When the door or window is opened, the
Hall sensor is separated from the magnet,
and the Hall sensor sends status “1”.
When the door or window is closed, the Hall
sensor is close to the magnet, and the Hall
sensor device sends status “0”.