background image

 

 

4.Set up Instruction

 

4.1

 

Power on and Turn on / off   

 

(1)

 

Power on:

 Insert batteries: open the battery cover; insert two sections of 3.6V ER14505 AA   

batteries and close the battery cover. 

(2)

 

Turn on

: if the device had never joined in any network or at factory setting mode, after powering 

on, the device is at off mode by default setting. Press and hold function key for 3 seconds till the 
green indicator flashes once and release to turn on device.   

(3)

 

Turn off: 

Press and hold function key for 5 seconds till the green indicator flashes quickly and 

release. The green indicator will flash 20 times to show that the device is turned off.       

   
 

Note:   

1.

 

The interval between shutting down twice or power off/on is suggested to be about 10   

  seconds to avoid the interference of capacitor inductance and other energy storage     
  components. 
2.

 

Do not press function key and insert batteries in the same time, otherwise, it will enter   

         engineer testing mode.   

3. Turn off operation is same with “Restore to Factory Setting” operation.   

4.2 Join Into LoRa Network   

To join the device into LoRa network to communicate with LoRa gateway. 
   
The network operation is as following: 
(1)

 

If the device had never joined any network, turn on the device; it will search an available LoRa     

   network to join. The green indicator will stay on for 5 seconds to show it joins into the network,     
   otherwise, the green indicator will be off. 
 
(2)

 

If R718IJK had been joined into a LoRa network, remove and insert the batteries;   

   it will repeat step (1).   
 

4.3 Function Key

 

(1)

 

Press and hold function key for 5 seconds to reset to factory setting. After restoring to   

   factory setting successfully, the green indicator will flashes quickly 20 times.     

(2) 

Press function key to turn on the device which is in the network and the green indicator will flash 

 

   once and the device will send a data report.      

 

Содержание R718IJK

Страница 1: ...18IJK User Manual Copyright Netvox Technology Co Ltd This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and...

Страница 2: ...tures 4 4 Set up Instruction 5 4 1 Power on and Turn on off 5 4 2 Join Into LoRa Network 5 4 3 Function Key 5 4 4 Data Report 6 5 Restore to Factory Setting 9 6 Sleeping Mode 10 7 Low Voltage Alarming...

Страница 3: ...with other communication methods LoRa spread spectrum modulation method greatly increases to expand the communication distance Widely used in long distance low data wireless communications For exampl...

Страница 4: ...3 2 Appearance Fig 1 R718IJK Appearance Indicator Function Key GND ADC 0 24V RED Black RED Black GND 4 20mA Yellow White Dry Contact...

Страница 5: ...WANTM Class A Frequency hopping spread spectrum Protection class IP65 Configuration parameters can be configured via a third party software platform data can be read and alerts can be set via SMS text...

Страница 6: ...ponents 2 Do not press function key and insert batteries in the same time otherwise it will enter engineer testing mode 3 Turn off operation is same with Restore to Factory Setting operation 4 2 Join...

Страница 7: ...0 1V ADCRawValue Change 0x64 100 mV Must more than 0x50 80 mV CurrentChange 0x02 2 mA Note The device send data cycle depends on real burning configuration The interval between two reports must be th...

Страница 8: ...00 Current configuration Config ReportReq R718IJK 0x01 0x5C MinTime 2bytes Unit s MaxTime 2bytes Unit s Battery Change 1byte Unit 0 1 v ADCRawValue Change 2byte Unit 1mV CurrentChange 1byte Unit 1mA R...

Страница 9: ...to MaxTime MinTime duration regardless BtteryVoltageChange value Example 2 based on MinTime 15 Minutes MaxTime 1 Hour Reportable Change i e BatteryVoltageChange 0 1V MaxTime Sleeping MinTime sleeping...

Страница 10: ...ta variation button pushed or MaxTime interval another cycle of MinTime MaxTime calculation is started 5 Restore to Factory Setting R718IJK saves data including network key information configuration i...

Страница 11: ...inutes After two minutes it will wake up every 15 minutes to request to join the network If it s at B status to prevent this unwanted power consumption we recommend that users remove the batteries to...

Страница 12: ...stroy batteries and deform or melt some plastic parts Do not store in a cold place Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do...

Отзывы: