5. Data Report
Data report configuration and sending period are as following:
Min Interval
(Unit:second)
Max Interval
(Unit:second)
Reportable Change
Current Change
≥
Reportable Change
Current Change
<
Reportable Change
Any number between
1~65535
Any number between
1~65535
Can not be 0
Report
per Min Interval
Report
per Max Interval
The device will immediately send a version packet report along with an uplink packet including reed switch status and battery
voltage.
The device sends data according to the default configuration before any other configuring.
Default setting:
MaxTime : Max Interval = 60 min = 3600s
MinTime : Min Interval = 60 min = 3600s (Default: Every Min Interval will detect the current voltage.)
BatteryVoltageChange: 0x01 (0.1V)
Reed switch trigger status:
When the magnet closes to the reed switch, it will report the status “0”
*The distance between the magnet and the reed switch is less than 2 cm
When the magnet removes the reed switch, it will report the status “1”
*The distance between the magnet and the reed switch is greater than 2 cm
Note:
The cycle of the device sending the data report is according to the default.
The interval between two reports must be the Mintime.
Please refer Netvox
LoRaWAN Application Command document
and
Netvox Lora Command Resolver