background image

 

5. Data Report   

 

Data report configuration and sending period are as following: 

 

Min Interval 

(Unit:second) 

Max Interval 

(Unit:second) 

Reportable Change 

Current Change

≥ 

Reportable Change 

Current Change

Reportable Change 

Any number between 

1~65535 

Any number between 

1~65535 

Can not be 0. 

Report 

per Min Interval 

Report 

per Max Interval 

The device will immediately send a version packet report along with two uplink packets including temperature, battery voltage, 

tilt angle of the X, Y, and Z axes. 

The device sends data in the default configuration before any configuration is done. 

Default Setting: 

MaxTime: Max Interval = 60 min = 3600s 

MinTime: Max Interval = 60 min = 3600s 

BatteryChange = 0x01 (0.1v) 

AngleChange = 0x05 (5°)

 

ActiveThreshold = 0x0003        (Range:0x0003-0x00FF)

 

Deactivetime = 0x05 (5 seconds)    (Range:0x0003-0x00FF) 

TemperatureChange = 0x0A (1°) 

R718EA Reporting Requirements: 

When R718EA detects one of the three-axis tilt, and the change amount of angle is equal/greater than the set AngleChange, it 

would report at MinTime. R718EA would also report at MinTime while detects the surface temperature changes. 

 

The data of three-axis accelerometer of the device needs to be lower than InActiveThreshold (cannot be modified) and the 

duration has to be more than 5 seconds before the next detection. If tilt or vibration continues to occur during this process, it 

would restart the timer. 

Note:   

(1)

 

R718EA is using three-axis accelerometer to detect tilt. 

(2)

 

The device report interval will be programmed based on the default firmware which may vary. 

(3)

 

The interval between two reports must be the minimum time. 

Please refer Netvox 

LoRaWAN Application Command document

 and 

Netvox Lora Command Resolver

 

http://www.netvox.com.cn:8888/page/index

 to resolve uplink data. 

Содержание R718EA

Страница 1: ...oprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties in whole or in part without written p...

Страница 2: ...rt 7 5 1 ActiveThreshold and InActiveThreshold 8 5 2 Offset calibration 8 5 3 Example of data configuration 8 6 Installation 11 7 Information about Battery Passivation 12 7 1 To determine whether a ba...

Страница 3: ...th other communication methods LoRa spread spectrum modulation method greatly increases to expand the communication distance Widely used in long distance low data wireless communications For example a...

Страница 4: ...parameters can be configured through third party software platforms data can be read and alarms can be set via SMS text and email optional Available third party platform Actility ThingPark TTN MyDevi...

Страница 5: ...green indicator stays on for 5 seconds success The green indicator remains off fail Had joined the network Turn on the device to search the previous network The green indicator stays on for 5 seconds...

Страница 6: ...ta report according to Min Interval The device is on but not in the network First two mins wake up every 15 seconds to send request After two mins enter sleeping mode and wake up every 15 minutes to s...

Страница 7: ...5 5 seconds Range 0x0003 0x00FF TemperatureChange 0x0A 1 R718EA Reporting Requirements When R718EA detects one of the three axis tilt and the change amount of angle is equal greater than the set Angle...

Страница 8: ...teger as 16 5 2 Offset calibration The accelerometer is a mechanical structure that contains components that can move freely These moving parts are very sensitive to mechanical stress far beyond solid...

Страница 9: ...ed 0x00 GetActiveThresholdReq 0x04 Reserved 9Bytes Fixed 0x00 GetActiveThresholdRsp 0x84 Threshold 2Bytes Deactivetime 1Byte Unit 1s Reserved 6Bytes Fixed 0x00 1 Configure device parameters MinTime 1m...

Страница 10: ...leeping sleeping 0H 15th M 30th M 45th M 1H 1H 10th M 1H 25th M 1H 40th M 1H 55th M 2H 10th M Wakes up and collects data 3 6V Does not report Wakes up and collects data 3 6V Does not report Wakes up a...

Страница 11: ...r cycle of MinTime MaxTime calculation is started 6 Installation While installing it is recommended to install R718EA while the device is power off and be installed horizontal at a stationary place Af...

Страница 12: ...ation may also lead to voltage delay when the batteries are put into operation and our devices may not work correctly in this situation As a result please make sure to source batteries from reliable v...

Страница 13: ...elt some plastic parts Do not store the device in places that are too cold Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not thro...

Отзывы: