7
Restore configuration:
Description
Device CmdID
DeviceType
NetvoxPayLoadData
SetRestore
ReportReq
R718DA
0x03
0x1A
RestoreReportSet (1byte)
0x00_DO NOT report when sensor restore
0x01_DO report when sensor restore
Reserved
(8Bytes,Fixed 0x00)
SetRestore
ReportRsp
0x83
Status
(0x00_success)
Reserved
(8Bytes, Fixed 0x00)
GetRestore
ReportReq
0x04
Reserved
(9Bytes, Fixed 0x00)
GetRestore
ReportRsp
0x84
RestoreReportSet (1byte)
0x00_DO NOT report when sensor restore
0x01_DO report when sensor restore
Reserved
(8Bytes,Fixed 0x00)
(3) Do report after sensor stops vibrating
Downlink
:
031A010000000000000000 (0x01_DO report when sensor restore)
Response
:
831A000000000000000000 (Configuration success)
831A010000000000000000 (Configuration failure)
(2) Read restore function:
Downlink
:
041A000000000000000000
Response
:
841A010000000000000000 (Current configuration) (report when sensor restore)
Example for MinTime/MaxTime logic:
Example#1
based on MinTime = 1 Hour, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange=0.1V
MaxTime MaxTime
Sleeping(MinTime)
Sleeping(MinTime)
Note: MaxTime=MinTime. Data will only be report according to MaxTime (MinTime) duration regardless BatteryVoltageChange
value.
Wake up and collects data
REPORTS 3.6V
Wakes up and collects data
REPORTS 3.6V
Wakes up and collects data
REPORTS 3.6V