background image

 

 

Example#2

 based on MinTime = 15 Minutes, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange= 0.1V. 

 

 

                                    

 

MaxTime

 

 

 

 

 

Sleeping(MinTime)       

  

  sleeping             sleeping  

  

        sleeping 

 

 

0H

                 15

th

 M               30

th

 M            45

th

 M               

1H

                                                 

          

 

 

 

 

 
 

Example#3 

based on MinTime = 15 Minutes, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange= 0.1V. 

 

 

                                                                                                       

MaxTime 

 

 

 

 

    

 

sleeping             sleeping

 

        ...

 

 

 

0H

             15

th

 M            

30

th

 M 

          45

th

 M              1H  

1H 10

th

 M

     1H 25

th

 M           1H 40

th

 M        1H 55

th

 M       

2H 10

th

 M

                    

 

 

 

 

 

 

 

 

 

Notes : 

1)

 

The device only wakes up and performs data sampling according to MinTime Interval. When it is sleeping, it does not collect 

data. 

2)

 

The data collected is compared with the last data reported. If the data variation is greater than the ReportableChange value, the 

device reports according to MinTime interval. If the data variation is not greater than the last data reported, the device reports 

according to MaxTime interval. 

3)

 

We do not recommend to set the MinTime Interval value too low. If the MinTime Interval is too low, the device wakes up 

frequently and the battery will be drained soon. 

4)

 

Whenever the device sends a report, no matter resulting from data variation, button pushed or MaxTime interval, another cycle 

of MinTime/MaxTime calculation is started. 

 

 

 

 

 

 

 

 

Wakes up and 

collects data 

3.6V   

Does not report   

Wakes up and 

collects data 

3.6V 

Does not report 

 

 

Wakes up and 

collects data 

3.6V 

Does not report   

 

 

Wakes up and 

collects data 

REPORTS 3.6V 

 

Wakes up and 

collects data 

REPORT 3.6V 

Wakes up and 

collects data 

REPORTS 3.6V 

 

Wakes up and collects data 

3.5V |3.5-3.6|=0.1 

REPORTS 3.5V 

Wakes up and 

collects data 

3.5V   

Does not report   

Wakes up and 

collects data 

3.5V   

Does not report   

Wakes up and 

collects data   

3.5V   

Does not report   

Wakes up and 

collects data 3.5V 

Does not report 

 

 

 

 

Wakes up and 

collects data     

3.5V   

Does not report   

 

Wakes up and 

collects data 

REPORTS 3.5V 

Wakes up and 

collects data 

3.6V 

  Does not report   

Users push the button, 

REPORTS 3.5V. 

Recalculate MaxTime. 

 

 

 

Содержание R718AB

Страница 1: ...ology Co Ltd This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties...

Страница 2: ...eport 5 5 1 Example of ReportDataCmd 5 5 2 Example of ConfigureCmd 6 5 3 Example for MinTime MaxTime logic 7 6 Installation 9 7 Information about Battery Passivation 11 7 1 To determine whether a batt...

Страница 3: ...reatly increases to expand the communication distance Widely used in long distance low data wireless communications For example automatic meter reading building automation equipment wireless security...

Страница 4: ...oftware platform data can be read and alerts can be set via SMS text and email optional Applicable to third party platforms Actility ThingPark TTN MyDevices Cayenne Improved power management for longe...

Страница 5: ...etwork Turn on the device to search the network to join The green indicator stays on for 5 seconds success The green indicator remains off fail Had joined the network not at factory setting Turn on th...

Страница 6: ...nge Reportable Change Any number between 1 65535 Any number between 1 65535 Can not be 0 Report per Min Interval Report per Max Interval The device will immediately send a version packet report along...

Страница 7: ...yte 000000 Reserved Example of Uplink 01130124FF391A9E000000 1st byte 01 Version 2nd byte 13 DeviceType 0x13 R718AB 3rd byte 01 ReportType 4th byte 24 Battery 24 HEX 36 DEC 36 0 1v 3 6v 5th 6th byte F...

Страница 8: ...me Note MaxTime MinTime Data will only be report according to MaxTime MinTime duration regardless BatteryVoltageChange value Description Device Cmd ID Device Type NetvoxPayLoadData Config ReportReq R7...

Страница 9: ...ecommend to set the MinTime Interval value too low If the MinTime Interval is too low the device wakes up frequently and the battery will be drained soon 4 Whenever the device sends a report no matter...

Страница 10: ...nsmission of the device The figure shows the scene where the temperature and humidity sensor R718AB is applied in the refrigerator It can also be applied to the following scenarios Restaurant refriger...

Страница 11: ...ut the lid back on and tighten the four screws Note Please do not disassemble the device unless it is required to replace the batteries Do not touch the waterproof gasket LED indicator light function...

Страница 12: ...orage period is more than one month from the date of battery production all the batteries should be activated If encountering the situation of battery passivation users can activate the battery to eli...

Страница 13: ...elt some plastic parts Do not store the device in places that are too cold Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not thro...

Отзывы: