5
5. Data Report
Data report configuration and sending
period are as following:
5.1 Example of ReportDataCmd
FPort
:
0x06
Bytes
1
1
1
Var(Fix=8 Bytes)
Version
DeviceType Report
Type
NetvoxPayLoadData
Version
– 1 byte –0x01
——
the Version of NetvoxLoRaWAN Application Command Version
DeviceType
– 1 byte – Device Type of Device
The device
type is listed in Netvox LoRaWAN Application Devicetype doc
ReportType
– 1 byte –the presentation of the NetvoxPayLoadData
,
according the devicetype
NetvoxPayLoadData
– Fixed bytes (Fixed =8bytes)
Min Interval
(Unit:second)
Max Interval
(Unit:second)
Reportable Change
Current Change≥
Reportable Change
Current Change
<
Reportable Change
Any number between
1~65535
Any number between
1~65535
Can not be 0.
Report
per Min Interval
Report
per Max Interval
When the device is powered on and activated, it will immediately send a version package.
Data will be reported once per hour by default setting.
Default setting:
Maximum time: 3600s
Minimum time: 3600s
BatteryChange: 0x01 (0.1V)
Illuminance
Threshold:
The device samples the illumination according to the Min Interval. When the illumination exceeds the set threshold, a
report will be sent.
Illuminance
Threshold: 0x00FF (255 LUX) // The threshold setting range is 0x0000-0x0BB8 (0~3000 LUX)
Note:
The reported data is decoded by the Netvox LoRaWAN Application Command document and