background image

 

 

4.

 

Set up Instruction 

On/Off 

 

Power on 

Insert batteries. (users may need a screwdriver to open);   

(Insert two sections of 3V CR2450 button batteries and close the battery cover.) 

Turn on   

Press any function key, and the indicator flashes once.   

Turn off 

(Restore to factory setting) 

Press and hold the function key for 5 seconds, and the green indicator flashes 20 times. 

Power off 

Remove Batteries.   

Note: 

1. Remove and insert the battery; the device memorizes previous on/off state by default. 

2. On/off interval is suggested to be about 10 seconds to avoid the interference of capacitor     

inductance and other energy storage components. 

3. Press any function key and insert batteries at the same time; it will enter engineer testing mode.   

Network Joining 

 

Never joined the network 

Turn on the device to search the network. 

The green indicator stays on for 5 seconds: success 

The green indicator remains off: fail 

Had joined the network 

Turn on the device to search the previous network. 

The green indicator stays on for 5 seconds: success 

The green indicator remains off: fail 

Fail to join the network 

Suggest to check the device verification information on the gateway or consult your platform 

server provider. 

Function Key 

 

Press and hold for 5 seconds 

Restore to factory setting / Turn off 

The green indicator flashes 20 times: success 

The green indicator remains off: fail 

Press once   

The device is in the network: green indicator flashes once and sends a report 

The device is not in the network: green indicator remains off 

Sleeping Mode 

 

The device is on and in the 

network 

Sleeping period: Min Interval. 

When the reportchange exceeds setting value or the state changes, a data report will be sent 

according to Min Interval.   

Low Voltage Warning 

Low Voltage 

2.4V 

Содержание R311FD

Страница 1: ...logy Co Ltd This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties...

Страница 2: ...atures 3 4 Set up Instruction 4 5 Data Report 5 5 1 ActiveThreshold and InActiveThreshold 6 5 2 Calibration 6 5 3 Example of ConfigureCmd 7 5 4 Example of MinTime MaxTime logic 9 5 5 The X Y Z axis di...

Страница 3: ...methods LoRa spread spectrum modulation technique greatly extend the communication distance It can be widely used in any use case that requires long distance and low data wireless communications For e...

Страница 4: ...be configured through third party software platforms data can be read and alarms can be set via SMS text and email optional Available third party platform Actility ThingPark TTN MyDevices Cayenne Low...

Страница 5: ...n the device to search the network The green indicator stays on for 5 seconds success The green indicator remains off fail Had joined the network Turn on the device to search the previous network The...

Страница 6: ...locity s 1 After the three axis acceleration of the device exceeds ActiveThreshold a report is sent immediately to report the three axis acceleration and velocity 2 After reporting the three axis acce...

Страница 7: ...d be set 10 9 8 0 0625 16 32 Active Threshold would be set integer as 16 5 2 Calibration The accelerometer is a mechanical structure that contains components that can move freely These moving parts ar...

Страница 8: ...n failure 2 Read Configuration Downlink 02C7000000000000000000 Response 82C7003C003C0100010000 Current configuration Description Device Cmd ID Device Type NetvoxPayLoadData Config ReportReq R311FD 0x0...

Страница 9: ...ice current parameter Description Device Cmd ID Device Type NetvoxPayLoadData SetActive ThresholdReq R311FD 0x03 0xC7 ActiveThreshold 2Bytes InActiveThreshold 2Bytes Reserved 5Bytes Fixed 0x00 SetActi...

Страница 10: ...Time Sleeping Min Time Sleeping Min Time 1H 2H 3H Note MaxTime MinTime Data will only be report according to MaxTime MinTime duration regardless BatteryVoltageChange value Example 2 based on MinTime...

Страница 11: ...ot recommend to set the MinTime Interval value too low If the MinTime Interval is too low the device wakes up frequently and the battery will be drained soon 4 Whenever the device sends a report no ma...

Страница 12: ...elt some plastic parts Do not store the device in places that are too cold Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not thro...

Отзывы: