5
5. Data Report
Data report configuration and sending period are as following:
Example of ConfigureCmd
FPort
:
0x07
Bytes
1
1
Var (Fix =9 Bytes)
CmdID
DeviceType
NetvoxPayLoadData
CmdID
– 1 byte
DeviceType
– 1 byte – Device Type of Device
NetvoxPayLoadData
– var bytes (Max=9bytes)
Min Interval
(Unit:second)
Max Interval
(Unit:second)
Reportable Change
Current Change
≥
Reportable Change
Current Change
<
Reportable Change
Any number between
1~65535
Any number between
1~65535
Can not be 0.
Report
per Min Interval
Report
per Max Interval
When the device is turned on, it will immediately send a version package.
Data will be reported by default setting before any configuration.
Default setting:
Maximum time: 3600s
Minimum time: 3600s
BatteryChange: 0x01 (0.1V)
The reported data is decoded by the Netvox LoRaWAN Application Command document and
http://www.netvox.com.cn:8888/page/index
Note:
The real data sending cycle is subject to the programming configuration before shipment.