5
Low Voltage Warning
Low Voltage
2.4V
5. Data Report
After power on, the device will immediately send a version packet report and a data report including reed switch status, glass
break status and voltage.
The device sends data according to the default configuration before any other configuring.
Default setting:
Report MaxTime: 1H (3600s)
Report MinTime: 1H (3600s)
BatteryVoltageChange
:
0x01 (0.1V)
Triggering the reed switch:
When the reed switch detects the state changing, the report will be sent immediately.
The report (status1): Open: on; Close: off
* The main body and the external sensor share an I/O status1;
therefore, when either the main body or the external sensor is in the open state, the report status will be 1.
The report status will be 0 only when both the main body and the external sensor are closed.
Triggering the glass sensor:
When the glass breakage detector is triggered, the status2 is on.
Note:
1. The cycle of the device sending the data report is according to the default.
2. The interval between two reports must be the MinTime.
The device reported data parsing please refer to
Netvox LoraWAN Application Command document
and
Netvox Lora
Command Resolver
http://loraresolver.netvoxcloud.com:8888/page/index
Data report configuration and sending period are as following
:
Min Interval
(Unit: second)
Max Interval
(Unit: second)
Reportable Change
Current Change ≥
Reportable Change
Current Change
<
Reportable Change
Any number between
1~65535
Any number between
1~65535
Can not be 0
Report per Min Interval Report per Max Interval