NetThings Energy Manager Скачать руководство пользователя страница 2

8 STEPS 

TO A SUCCESSFUL INSTALLATION

1.

   Please choose a suitable location for the display and Energy Manager.*

2.  

Ensure that a 13A power supply is available at these chosen locations.

3.  

If your chosen location for the Energy Manager is not adjacent to the services you  

require monitored then run cabling between these during your first fix installation.

4.  

Fix Energy Manager and display in their final position and make connections.

5.  

Make connections to the service you require to be monitored.**

6.  

Pair the display to the Energy manager.

7.  

Use energy on systems that you have connected to and check that this registers on your display.

8.  

Leave information with the end user for them to gain maximum usage of this product

.

*As this product communicates with WiFi frequencies the signal from the Energy Manager should easily reach the display  

within modern houses but solid walls and obstructions can affect this. If you are in doubt about the effectiveness of the  

signal strength please check before installation. ** Additional equipment may be needed to connect to other manufacturer’s 

products. Please contact NetThings if in doubt.

IMPORTANT ALL WIRING SHOULD BE CARRIED  

OUT BY A COMPETENT INSTALLER OR ELECTRICIAN.
QUALIFIED TO WORK WITH MAINS ELECTRICITY AND  

BE IN ACCORDANCE WITH IEE & BUILDING REGULATIONS  

AND IN SOME CASES, NOTIFIABLE TO BUILDING CONTROL. 

DO NOT CARRY OUT THIS INSTALLATION IF UNDER  

THE INFLUENCE OF ALCOHOL OR DRUGS.

CAN CONNECT UP TO 3 PULSE O/P UTILITY METERS. 

PULSE INPUTS ARE AT LOW VOLTAGE. 

If you have any questions about installing 

this product please contact NetThings or  

visit www.netthings.co.uk/support

WATER METERS

Water meters need to be specified as pulse enabled. Polarity  

of pulse is not critical as pulses are mechanically generated.

GAS METERS

Ensure gas meters are pulse enabled and fitted with the  

appropriate pulse block. As there are several different types  

please ensure that the correct pulse block is ordered. 

If unsure check our support website for further information.  

www.netthings.co.uk/support

ELECTRIC METERS

If monitoring solar PV systems then fit an import export  

meter and connect Energy Manager via pulse cables. Polarity  

of connection is important here as it is an electronically  

generated pulse. Observe pulse polarity when connecting.

HEAT METERS

Heat meters require to be pulse enabled and with a low  

pulse setting i.e. 1 pulse per watt hour of energy.

Back Plate: 154mm x 86mm

Display screen is fitted to a double recessed box. 

Tablet in mount: 173mm x 99mm x 14mm 

Fused 3A Spur

Cable specification: Beldon 9501 or equivalent.

WARNING - Electric Shock Hazard! Make all cable connections to device  

before powering up the unit. Always power-down before disconnecting cables.

Direct Mounting 

(Cable restraints must be used)

Recessed Box

Surface Box

Fused  

3A Spur

Heat Meters

Gas Meters

Water Meters

Can Connect  

up to 3 x CTs

NETTHINGS MEASUREMENT  

UNIT BACKPLATE

 

upto 6 channels I/P  

plus power supply

CURRENT  

TRANSFORMERS

Three sizes are available

most commonly supplied is

CT16. If monitoring 3 phase

connect one CT to each phase

and connect to terminals

1-2, 3-4 & 5-6. CTs come with

cable attached - 

polarity  

isn’t important.

ELECTRICIAN

 

PLEASE READ THESE INSTRUCTIONS IMMEDIATELY ON 

RECEIPT OF THIS PRODUCT AND CARRY OUT  

STEPS 1 TO 3 AS SOON AS POSSIBLE

.

MOUNTING OPTIONS

The Energy Manager can be fitted in either of the following options:

Electric Meters

Outer cover clips over the backplate. 

Отзывы: