Where electrical components are being changed, they shall be fit for the purpose and to the correct
specification. At all times the manufacturer’s maintenance and service guidelines shall be followed.
If in doubt consult the manufacturer’s technical department for assistance.
The following checks shall be applied to installations using flammable refrigerants:
– The charge size is in accordance with the room size within which the refrigerant containing parts
are installed;
– The ventilation machinery and outlets are operating adequately and are not obstructed;
– If an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the
presence of refrigerant;
– Marking to the equipment continues to be visible and legible. Markings and signs that are illegible
shall be corrected;
– refrigeration pipe or components are installed in a position where they are unlikely to be exposed
to any substance which may corrode refrigerant containing components, unless the components are
constructed of materials which are inherently resistant to being corroded or are suitably protected
against being so corroded.

2.2.9 Checks to electrical devices

Repair and maintenance to electrical components shall include initial safety checks and component
inspection procedures. If a fault exists that could compromise safety, then no electrical supply shall
be connected to the circuit until it is satisfactorily dealt with. If the fault cannot be corrected
immediately but it is necessary to continue operation, an adequate temporary solution shall be used.
This shall be reported to the owner of the equipment so all parties are advised.
Initial safety checks shall include:
-those capacitors are discharged: this shall be done in a safe manner to avoid possibility of sparking;
-that there no live electrical components and wiring are exposed while charging, recovering or
purging the system;
-that there is continuity of earth bonding.

Содержание OL12-B015E

Страница 1: ...Home Dehumidifier User Manual OL12 B015E With R290 refrigerant READ AND SAVE THESE INSTRUCTIONS...

Страница 2: ......

Страница 3: ...Contents BEFORE YOU BEGIN 1 2 FOR YOUR SAFETY 3 6 INSTANNATION 7 8 PRODUCT OVERVIEW 9 10 OPERATION 11 15 MAINTANCE 16 17 TROUBLESHOOTING 18 19...

Страница 4: ...of its efficient energy properties R290 is highly suitable as a coolant for this application Special precautions must be taken into consideration due to the coolant s high flammability 1 2SYMBOLS FRO...

Страница 5: ...the atmosphere R 290 propane is flammable and heavier than air It collects first in low areas but can be circulated by the fans If propane gas is present or even suspected do not allow untrained perso...

Страница 6: ...product identification plate Always use a power outlet that is grounded Unplug the power cord when cleaning or when not in use Do not operate with wet hands Prevent water from spilling onto the unit...

Страница 7: ...not be installed in an unventilated space if that space is smaller than 8 m Compliance with national gas regulations shall be observed Keep any required ventilation openings clear of obstruction The...

Страница 8: ...refrigerants i e no sparking adequately sealed or intrinsically safe 2 2 5 Presence of fire extinguisher If any hot work is to be conducted on the refrigeration equipment or any associated parts appro...

Страница 9: ...ere they are unlikely to be exposed to any substance which may corrode refrigerant containing components unless the components are constructed of materials which are inherently resistant to being corr...

Страница 10: ...es or other products that products that produce heat in an area where oil or water may be splashed Direct sunlight Mechanical vibration or shock Excessive dust Lack of ventilation such as cabinet or b...

Страница 11: ...st 24 hours before start up Keep doors and windows close for better energy saving Do not operate or store the unit in direct sunlight or rain It is normal for air outlet to feel warm to touch after co...

Страница 12: ...9 4 PRODUCT OVERVIEW 4 1 FRONT VIEW BACK VIEW...

Страница 13: ...Low power consumption energy efficient A 24 hours timer to set the time of operation Quiet fan has two speed settings 4 3 SPECIFICATIONS MODEL NO OL12 B015E Dehumidify Capacity 12L day 30 RH80 Rated...

Страница 14: ...he unit is power on 6 Water Full LED red Lights up when water tank is full 7 Humidity LED orange Lights up when setting humidity 8 Fan speed LED high orange low blue Lights up when adjust the fan spee...

Страница 15: ...T key repeatedly to adjust humidity set point by increments of 5 The unit will cycle on and off to maintain the level Set the humidity level between 40 and 60 for comfort C Set Fan Speed Press SPEED k...

Страница 16: ...tart function When there is a power outage the dehumidifier automatically restarts when the power comes back on and also resumes settings H Automatic Defrost function At low room temperatures below 18...

Страница 17: ...properly 1 When the tank is full The unit will make a buzzing sound and the FULL light will turn on 2 Press the POWER button to turn off the unit 3 Pull on the water tank and simply slide out of the b...

Страница 18: ...in safe area Securely and properly connect the drain hose and make sure it is not kinked and clear of obstruction Place the outlet of hose over a drain or bucket and ensure that water could freely flo...

Страница 19: ...use damage to the unit The air filter requires regular cleaning The air filter is removable for easy cleaning Do not operate the unit without an air filter or the evaporator may be contaminated Pic4 S...

Страница 20: ...quipment PPE 4 Evacuate unnecessary personnel isolate and ventilate area 5 Do not get in eyes on skin or on clothing Do not breathe vapors or gas 6 Prevent entry to sewers and public waters 7 Stop the...

Страница 21: ...erflow while moving the unit Empty the water tank before transport Check if the drain hose is kinked or bends Straighten the hose to avoid a trap existing Excessive Noise Check if the unit is securely...

Страница 22: ...ARNING Releasing refrigerant into atmosphere is strictly forbidden Do not dispose of electrical appliances as unsorted municipal waste use separate collection facilities Contact your local government...

Страница 23: ...This product imported by Consumable Direct Ltd M32 0JT UK...