background image

NT205B User’s Manual

  

  

  

  

  VER_A1 

     

     

     

     

 

 

2

Copyright 

 

Copyright © 2011 by National Enhance Technology Corp. All rights reserved. 

 

Trademarks 

NETSYS is a trademark of National Enhance Technology Corp.   

Other brand and product names are registered trademarks or trademarks of their respective holders. 

 

Legal Disclaimer   

The information given in this document shall in no event be regarded as a guarantee of conditions or characteristics. With respect 

to any examples or hints given herein, any typical values stated herein and/or any information regarding the application of the 

device, National Enhance Technology Corp. hereby disclaims any and all warranties and liabilities of any kind, including without 

limitation warranties of non-infringement of intellectual property rights of any third party. 

 

Statement of Conditions 

In the interest of improving internal design, operational function, and/or reliability, NETSYS reserves the right to make changes to 

the products described in this document without notice. NETSYS does not assume any liability that may occur due to the use or 

application of the product(s) or circuit layout(s) described herein. 

 

Maximum signal rate derived form IEEE Standard specifications. Actual data throughput will vary. Network conditions and 

environmental factors, including volume of network traffic, building materials and construction, and network overhead lower actual 

data throughput rate.

 

Содержание NT205B

Страница 1: ...s s G G G s s sh h hd d ds s sl l l b b bi i is s s L L LA A AN N N E E Ex x xt t te e en n nd d de e er r r w w wi i it t th h h 4 4 4 E E Et t th h he e er r rn n ne e et t t U U Us s se e er r r s...

Страница 2: ...hereby disclaims any and all warranties and liabilities of any kind including without limitation warranties of non infringement of intellectual property rights of any third party Statement of Conditi...

Страница 3: ...DO NOT allow anything to rest on the power cord and do NOT locate the product where anyone can work on the power cord DO NOT install nor use your device during a thunderstorm There may be a remote ris...

Страница 4: ...ATION 8 1 4 SHDSLSYSTEM COMPONENTS 8 1 5 FRONT PANEL LEDS INDICATORS 8 1 6 REAR PANEL CONNECTORS 10 CHAPTER 2 PACKAGING 12 2 1 CHECKING PACKAGE CONTENTS 12 2 2 PREPARE FOR INSTALLATION 12 CHAPTER 3 LO...

Страница 5: ...ONFIGURE DSL RATE 21 4 4 CONFIGURE LAN INTERFACE 21 4 5 VLAN SETTING 23 4 6 FACTORY DEFAULT SETTING 25 4 7 SAVE CONFIGURATION 25 CHAPTER 5 PERFORMANCE MONITORING 26 CHAPTER 6 INVENTORY 28 APPENDIX A C...

Страница 6: ...igure the settings and to monitor the DSL connection status NT205B conforms to ITU T G 991 2 the GSHDSL requirements Each NT205B can be configured as either STU C for the central side or STU R for the...

Страница 7: ...x A Annex B and Annex F selectable LAN interface Mac Address filtering bridge up to 2K Mac address learning Bridge IEEE 802 1D transport self learning VLAN Tag based Port Based Bandwidth Control for E...

Страница 8: ...o point application for user interface LAN Ethernet Bridging 1 4 SHDSL system components NT205B modem CO or NT205B modem RT in a working pair 1 5 Front Panel LEDs Indicators There are eight LED indica...

Страница 9: ...configured to RT mode DSL Orange Steady Blinking Off The device is Sync Status The link is synchronizing this may take several minutes The device is unplugged or disconnected LN1 Orange Steady Link 1...

Страница 10: ...T205B s rear panel meets to IEEE 802 3 or IEEE 802 3u request and supports 10 100 Base T auto test and half all touble works model operation bridge can provide up to 128 MAC address and MAC address fi...

Страница 11: ...00 Base T pin out Pin NO Function Data Direction Designati on 1 TX Transmitting Data Toward the LAN network TX 2 TX Transmitting Data Toward the LAN network TX 3 RX Receiving Data Toward the LAN Equip...

Страница 12: ...05B User Manual 2 2 Prepare for Installation Connecting the NT205B If configured from the Craft port your are encouraged to use the virtual terminal emulator from Window Microsoft and set the COM Port...

Страница 13: ...s a blinking cursor to select various menus sub menus and fields within those menus To pop up the console press the Enter key several times to display the Log On Screen illustrated in the following sc...

Страница 14: ...gate the console screen refer to the table below for further details Keyboard Command Description Tab Tabs to previous item Space Refreshes the entire screen Esc Escapes to previous page 1 N Fields en...

Страница 15: ...RT 2 Annex Annex A Annex B Annex F 3 DSL Rate 3 89 AnnexF 3 36 Annex A B 4 LAN Port 1 Speed 10M 100M 2 Auto Negotiation Disable Enable 3 Duplex Half Full 4 Flow control Eable Disable 5 VLAN setting 1...

Страница 16: ...Bandwidth Value 1 89 N 64Kbps 6 Factory Default 7 Save 2 Status 1 Device Type COT RT 2 Annex Annex A Annex B Annex F 3 DSL Rate 64 5696 kbps 4 S N 0 20dB 5 DSL Status Idel SYN Handshaking Trainning 3...

Страница 17: ...erarchy Status Alarm message This is the two line area above the double dotted line that provides network and user interface status and alarm message Sub Menu or Result This is the area above the sing...

Страница 18: ...t lists the function keys specific to the operation of the menu currently displayed Function Key Input Field Sub Menu Result Display Status Message Menu Sequence Main Cfg Device Type Line CNT Data Rat...

Страница 19: ...tention to the following notice 1 Regional DSL modes Annex A B F of STU C and STU R shall be set as the same Otherwise the DSL can not get sync 2 Given the same speed under 2304kbps the transmission d...

Страница 20: ...reen Refresh Table 5 1Configure Parameters Screen Content Item Description 1 Device Type Specifies whether the unit is configured as COT or RT Entry COT RT 2 Annex Sets the transmission mode for SHDSL...

Страница 21: ...tion sequence Local Configure Move cursor to 2 Annex and specify whether the DSL is configured as Annex A Annex B or Annex F 4 3 Configure DSL Rate To configure the DSL Rate apply the menu selection s...

Страница 22: ...Port 1 Port 2 Port 3 Port 4 C COT SYNC 4032 kbps LINK DOWN DOWN DOWN R RT SYNC 4032 kbps LINK DOWN DOWN DOWN 1 Auto Negotiation Disable 2 Speed 100M 3 Duplex Full 4 Flow control Enable 1 Disable 2 En...

Страница 23: ...Manually mode Entry Disable Enable 2 Mode Specifies the operating speed of LAN port Entry 10M 100M 3 Duplex Specifies whether the Ethernet interface is being operating in Half or Full duplex mode Entr...

Страница 24: ...ed Vlan These two implementation of VLAN can NOT work together User should configure one option at one time For P P segmented Channel implement there is a typical application The LAN ports P1 P4 at tw...

Страница 25: ...efault configuration setup is provided To default the setting follow the steps described below The Local Cfg screen appears when the Local Configuration menu sequence is entered Position the cursor at...

Страница 26: ...d Packets for each LAN port follow the menu entering sequence Local Statue Main Status Device Type Line CNT Data Rate Port 1 Port 2 Port 3 Port 4 C COT SYNC 4032 kbps LINK DOWN DOWN DOWN R RT SYNC 403...

Страница 27: ...signal to noise ration SNR 5 DSL Status Display the current DSL Status 6 LAN 1 Rx Tx packet Displays the total number of received transmitted Packets through the LAN port 1 7 LAN 2 Rx Tx packet Displ...

Страница 28: ...m Description 1 S W Version Displays the software version currently used for the unit 2 H W Version Displays the hardware version of circuitry 3 DSL Vserion Displays the DSL version of circuitry Main...

Страница 29: ...d on the user is encouraged to try to correct the interference by one or more of the following measures 1 Reorient or relocate the receiving antenna 2 Increase the separation between the equipment and...

Страница 30: ...essible Caution Use only the power supply included with this product In the event the power supply is lost or damaged In the United States use only with CSA certified or UL listed Class 2 power supply...