A.2 Telephone wire 

Standard telephone wire of any gauge or type-flat, twisted or quad is used to connect the Modem to the telephone network. 

A telephone cable typically consists of three pairs of wires, one of which is used for transmission. The connector at the end 

of the telephone cable is called an RJ-11 connector and it consists of six pins. POTS (plain old telephone services) use pins 

3 and 4 for voice transmission. A telephone cable is shown below. (

Figure A-4

 

A

B

 

Figure A-4 Telephone cable 

The A and B connectors on the rear of the Modem are RJ-11 connectors. These connectors are wired identically. The 

RJ-11 connectors have six positions, two of which are wired. The Modem uses the center two pins. The pin out 

assignment for these connectors is presented below. (

Table A-2

 

Table A-2 RJ-11 Pin out Assignments 

Pin# 

MNEMONIC 

FUNCTION 

NC 

Unused 

NC 

Unused 

TIP 

POTS 

RING 

POTS 

NC 

Unused 

NC 

Unused_ 

Содержание NH-300SP

Страница 1: ...0S S SP P P 2 2 2E E Et t th h he e er r rn n ne e et t t H H HP P PN N NA A A M M Mo o od d de e em m m w w wi i it t th h h s s sp p pl l li i it t tt t te e er r r U U US S SE E ER R R S S S M M MA...

Страница 2: ...s of any third party Statement of Conditions In the interest of improving internal design operational function and or reliability NETSYS reserves the right to make changes to the products described in...

Страница 3: ...ccess the internet on the same wire simultaneously It even allows staying connected 24 hours on internet connections thus eliminating dial up prior to internet access The benefit of Modem allows multi...

Страница 4: ...em distributes bandwidth inside the building for applications that uses T 1 E 1 xDSL Cable modems IEEE 802 11b outdoor wireless connections Attention Be sure to read this manual carefully before using...

Страница 5: ...r them DO NOT allow anything to rest on the power cord and do not locate the product where anyone can work on the power cord DO NOT install nor use your device during a thunderstorm There may be a rem...

Страница 6: ...INDICATORS 9 Chapter 3 Installing the Modem 11 3 1 HARDWARE INSTALLATION 11 3 2 PRE INSTALLATION REQUIREMENTS 11 3 3 GENERAL RULES 12 3 4 CONNECTING THE MODEM 12 3 5 CONNECTING THE RJ 11 PORTS 13 Chap...

Страница 7: ...NH 300SP 2Ethernet HPNA Modem USER S MANUAL Ver A 7 6 Warranty 30 Chinese SJ T 11364 2006 31...

Страница 8: ...C 5V 1A Power Adapter 1 x RJ 45 Cable 1 x RJ 11 cable Note1 Please inform your dealer immediately for any missing or damaged parts If possible retain the carton including the original packing material...

Страница 9: ...8 Chapter 2 Hardware Description This section describes the important parts of the Modem It features the front indicators and rear connectors NH 300SP Outlook 2 1 Front Panel The following figure show...

Страница 10: ...n LEDs Color Status Descriptions On The device is receiving the power and functioning properly Power Green Off The device is not ready or has malfunctioned On The device has a good Ethernet connection...

Страница 11: ...2 2 Rear side of the Modem Table 2 2 Connectors shown on the rear side of the Modem Connectors Type Description Line RJ 11 For connecting to the RJ 11 wall jack Using a RJ 11 cable Phone RJ 11 Must b...

Страница 12: ...hardware installation make sure you can provide the right operating environment including power requirements sufficient physical space and proximity to other network devices that are to be connected...

Страница 13: ...net port which support connection to Ethernet operation The devices attached to these ports must support auto negotiation or 10Base T or 100Base TX unless they will always operate at half duplex Use a...

Страница 14: ...ng Every RJ 11 modular phone jack in the home can become a port on the LAN Multiple PC peripherals or networking devices can be installed on a single telephone wire that can span within 500M 1600 feet...

Страница 15: ...d use only twisted pair cables with RJ 45 connectors that conform to FCC standard Notes 1 Be sure each twisted pair cable RJ 45 does not exceed 100 meters 333 feet 2 RJ 11 port use 18 24 gauge phone w...

Страница 16: ...1 T 1 Lease Line xDSL wireless connections or etc connecting to a IP sharing device using the RJ45 line to connect to the Modem Ethernet port Figure 3 2 RJ 11 cable Figure 3 2 Ethernet Connecting Appl...

Страница 17: ...L or wireless modem To install the Modem or to access the Internet you simply plug into your existing telephone jacks just like you would for a telephone modem or a fax machine There is no need for sp...

Страница 18: ...L Ver A 7 17 Power Ethernet HomeRun NH 200 Link Active RJ 11 RJ 11 RJ 11 RJ 11 Internet To PSTN V 90 Modem xDSL Modem Cable Modem Wireless Modem Home Office Kitchen Living Room Kid s Bedroom Figure 4...

Страница 19: ...ht pins The Ethernet standard uses pins 1 2 3 and 6 for data transmission purposes Table A 1 Table A 1 RJ 45 Ethernet Connector Pin Assignments MDI MDI X PIN Signal Media Dependant interface Signal Me...

Страница 20: ...NH 300SP 2Ethernet HPNA Modem USER S MANUAL Ver A 7 19 Figure A 2 Pin Assignments and Wiring for an RJ 45 Straight Through Cable Figure A 3 Pin Assignments and Wiring for an RJ 45 Crossover Cable...

Страница 21: ...onsists of six pins POTS plain old telephone services use pins 3 and 4 for voice transmission A telephone cable is shown below Figure A 4 A B Figure A 4 Telephone cable The A and B connectors on the r...

Страница 22: ...r power up to 500 meters with 24 gauge phone wire Build in POTS ISDN filter splitter Connects 10 100Base T to HomePNA Provides two RJ 11 for HomePNA Line port and two RJ 45 for 10 100Base T port Suppo...

Страница 23: ...ate 148 800 packets second for 100Mbps 1 488 packets second for 1Mbps Band Pass Spectrum 5 5Mhz 9 5Mhz Splitter Spectrum 0 1 1Mhz MAC Address Table 2K Queue Buffer 2k bits per block Switching Methods...

Страница 24: ...wer cord with another device If these measures fail to resolve the problem have the unit power supply replaced by a qualified distributor 2 Symptom Link indicator does not light up green after making...

Страница 25: ...g the power cord or network cabling test them in an alternate environment where you are sure that all the other components are functioning properly Transmission Mode The default method of selecting t...

Страница 26: ...ms occur after altering the network configuration restore the original connections and try to track the problem down by implementing the new changes one step at a time Ensure that cable distances and...

Страница 27: ...equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures 1 Reorient or relocate the receiving antenna 2 Increase the separation between t...

Страница 28: ...essible Caution Use only the power supply included with this product In the event the power supply is lost or damaged In the United States use only with CSA certified or UL listed Class 2 power supply...

Страница 29: ...Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at owner s expense CE Mark Warning This is...

Страница 30: ...r A 7 29 Appendix E Attaching Rubber Feet 1 Make sure mounting surface on the bottom of the Modem is grease and dust free 2 Apply the Rubber Feet to each corner on the bottom of the Modem These footpa...

Страница 31: ...any misuse neglect or accidental damage or which contain defects which are in any way attributable to improper installation or to alteration or repairs made or performed by any person not under contro...

Страница 32: ...NH 300SP 2Ethernet HPNA Modem USER S MANUAL Ver A 7 31 Chinese SJ T 11364 2006 Pb Hg Cd Cr VI PBB PBDE SJ T 11364 2006 SJ T 11364 2006...