Netstor NS780S-G3 Скачать руководство пользователя страница 1

First edition, Oct. 2019

User Manual

NS780S-G3

Desktop 16-Bay PCIe to SAS/SATA Enclosure

Содержание NS780S-G3

Страница 1: ...First edition Oct 2019 User Manual NS780S G3 Desktop 16 Bay PCIe to SAS SATA Enclosure...

Страница 2: ...n Off 12 7 Operation 14 4 Enclosure Setup 6 3 Panel Layout 5 6 RAID Card HBA Card Installation 8 Hard Drive Installation 14 LED Status on Host card and Target card 15 macOS operating system 15 Windows...

Страница 3: ...ight 19 9 2 Global HDD LED showing red light Appendix The Functions on Backplane 20 20 1 Function of Backplane Drive Fault LED SW1 1 21 5 Global HDD LED fault indicator jumper 21 3 Function of LED act...

Страница 4: ...HD 1920 1080 and 3D animation Featuring easy setup of the enclosure the NS780S G3 can be easily connected to host computer through only one data cable connectivity Before installing this unit verify...

Страница 5: ...5 Global HDD LED Reading writing blue Periodic access ashing blue HDD failure red go to page 19 for the detail Rebuilding interlacing of ashing blue and ashing red 4 Temperature LED Green temperature...

Страница 6: ...G3 from its packaging and place the enclosure on the even surface close to the computer 2 Loosen the two thumbscrews and remove the side door from NS780S G3 3 Detach the pillar under the sixteen drive...

Страница 7: ...S780S G3 backplane Connect the topmost mini SAS connector labeled SAS Port 1 on backplane to Channel 1 4 mini SAS connector on RAID HBA the second connector labeled SAS Port 2 to Channel 5 8 mini SAS...

Страница 8: ...drive tray and then pull the tray out of the enclosure 8 Place the drive tray on a at surface and then attach the hard drive into the tray 6 Restore the pillar back to the original state by tightening...

Страница 9: ...the tray as shown in the picture below 10 Insert the drive tray containing the HDD into the NS780S G3 enclosure correctly and then tighten the thumbscrew on the tray 11 Go over steps 7 to 10 again fo...

Страница 10: ...slot compatible with PCIe 3 0 16 slot in the computer and then secure the host adapter with a screw 2 Connect one end of the PCIe 8 data cable to the external PCIe 3 0 8 connector on NS780S G3 host a...

Страница 11: ...ata cable connector must be at the same side as Nestor host card and target card s obverse side when cable is connected to the host target card 3 Connect the other end of the PCIe 8 data cable to the...

Страница 12: ...he NS780S G3 by the host computer the other is to power on off the Netstor unit manually Switch SW1 4 on the backplane within the Netstor unit determines whether to power the Netstor storage on or off...

Страница 13: ...ue light to power on the Netstor unit And then power on your host computer 3 After the computer is shut down press and hold NS780S G3 enclosure s front LED button for over two seconds until the LED bu...

Страница 14: ...er and NS780S G3 is NOT linked SW1 switch When SW1 switch is turned to the left position the NP960AG3 card will be set as the host card The LED1 will show red light to indicate the NP960AG3 card is co...

Страница 15: ...o the user s manual of the RAID controller card that is installed in NS780S G3 Windows operating system 1 Verify the RAID card in NS780S G3 is recognized by host computer Right click This PC and selec...

Страница 16: ...e on the fan module The front two fans The front 120 120 25 mm cooling fan speed can be adjusted Pull out the fan module there are four sets of jumpers labeled with 6V 8V 10V 12V from top to bottom on...

Страница 17: ...jumper is placed over pin 1 and pin 2 for label F the fan spins at full speed If all the pins are open no jumper being placed over the pins the fan will not spin The rear two fans To adjust the fan s...

Страница 18: ...showing red light When one of the cooling fans within Netstor unit fails the fan LED in front of NS780S G3 enclosure will show red light The approach to distinguish which cooling fan in the Netstor un...

Страница 19: ...the web GUI from the last step locate the number of drive bay in the Netstor unit and you will see with the number of the failure drive it will show red light 9 2 Global HDD LED showing red light When...

Страница 20: ...ring varies according to different RAID card employed 2 Function of SAS HDD act state LED on Backplane SW1 2 There are sixteen HDD act state LEDs beside each HDD connector on the backplane inside the...

Страница 21: ...rd s SGPIO or the HDD itself The default setting is set to be the source coming from the HDD itself 4 Function of Power on off by Host or Manually SW1 4 This switch determines whether to power Netstor...

Отзывы: