NETGEAR SW510 - Switch Скачать руководство пользователя страница 9

 

Introduction

1-1

 

Chapter 1

Introduction

 

Congratulations on your purchase of the NETGEAR

 

 

 

Model SW510 10-port 10/100 Mbps Ethernet 

Switch or the NETGEAR Model SW518 18-port 10/100 Mbps Ethernet Switch. These switches 
are part of the NETGEAR

 

 

 500-series product family. The switches allow simultaneous 

transmission of multiple packets through an internal high-speed data channel, improving the 
overall information throughput and productivity of a network environment.

 

Benefits of Using Switching Technology

 

Ethernet switches increase network throughput by segmenting network traffic. Instead of 10 PCs 
all sharing a single 10 megabit per second (Mbps) network connection with an average of 1 Mbps 
per PC, a 10-port switch provides the same 10 PCs with 10 Mbps individually. By using the 
10-port switch, performance increases up to tenfold and is done with no change in network wiring, 
adapters, or software. As a result, performance upgrade is obtained very quickly and at a low cost. 

 

Overview of the Switches

 

The Model SW510 and Model SW518 switches can be utilized as either segment switches or 
desktop switches. A 

 

segment switch

 

 is designed to support an entire workgroup on each port, with 

each port having significant memory buffering and supporting hundreds of addresses (one or more 
addresses per PC). A segment switch also provides significant performance benefits over a shared 
hub. A 

 

desktop switch

 

 is designed to support one or a few PCs per port. A desktop switch is 

generally used where individuals within workgroups need 10 Mbps network throughput but also 
require 100 Mbps access.

The design of the Model SW510 and Model SW518 switches enables the use of the devices in the 
most demanding segment switching applications, yet pricing makes them very affordable for use 
in desktop applications.

 

SW510.bk  Page 1  Wednesday, March 12, 1997  10:49 AM

Содержание SW510 - Switch

Страница 1: ...March 1997 NETGEAR Inc A Bay Networks Company 48015 Warm Springs Blvd Fremont CA 94539 USA Installation Guide for the Model SW510 and Model SW518 Ethernet Switches SW510 bk Page i Wednesday March 12 1...

Страница 2: ...cations Operation of this equipment in a residential area is likely to cause harmful interference in which case users will be required to take whatever measures may be necessary to correct the interfe...

Страница 3: ...receivers Customer Support For assistance with installing and configuring your NETGEAR system or with post installation questions or problems contact your point of purchase representative To contact...

Страница 4: ...iv SW510 bk Page iv Wednesday March 12 1997 10 49 AM...

Страница 5: ...HDX FDX AUTO Duplex Toggle Switches 2 6 Chapter 3 Applications Desktop Switching 3 1 Network Segmentation 3 2 Bridging from 10 Mbps to 100 Mbps Networks 3 4 Chapter 4 Installation Site Preparation 4 1...

Страница 6: ...ration 5 2 Switch Integrity 5 2 Appendix A Technical Specifications General Specifications A 1 Appendix B Connector Pin Assignments RJ 45 Plug and vista RJ 45 Connector B 1 Appendix C Ethernet and Cab...

Страница 7: ...Model SW510 switch used as a desktop switch 3 2 Figure 3 2 Model SW518 switches used for network segmentation and as a multiport bridge to a high bandwidth backbone 3 3 Figure 3 3 Bridging from 10 Mb...

Страница 8: ...le 2 1 LED descriptions 2 4 Table B 1 Pin assignments for the RJ 45 plug and vista RJ 45 connector B 2 Table C 1 Electrical requirements of Category 3 4 and 5 cables C 2 SW510 bk Page viii Wednesday M...

Страница 9: ...to tenfold and is done with no change in network wiring adapters or software As a result performance upgrade is obtained very quickly and at a low cost Overview of the Switches The Model SW510 and Mod...

Страница 10: ...s are devices functioning on the media access control MAC layer they are protocol independent and are compatible with IEEE802 3 IEEE802 3u TCP IP NetWare DECnet and XNS protocols Each of these switche...

Страница 11: ...ic to the appropriate route without slowing down the traffic Plug and Play operation with no software to configure Low latency store and forward transmission mode with leading edge to leading edge of...

Страница 12: ...SW510 bk Page 4 Wednesday March 12 1997 10 49 AM...

Страница 13: ...wing the front panels of the switches Key 1 Power LED 2 Rx Tx and Collision LEDs for ports 1 through 10 3 100 Mbps LEDs for ports 9 and 10 4 10 Mbps Ethernet ports1 through 8 with Link and FDX LEDs on...

Страница 14: ...e are sixteen 10 Mbps ports and two 10 100 Mbps ports A server or PC can be connected to any of the ports The 10 100 Mbps ports are Ports 9 and 10 on the Model SW510 switch and Ports 17 and 18 on the...

Страница 15: ...link Push Button As illustrated in Figure 2 1 and Figure 2 2 one 10 Mbps port and one of the 10 100 Mbps ports on each of the switches is equipped with a Normal Uplink push button that allows you to s...

Страница 16: ...transmission or reception is occurring on the port The blinking action corresponds to the amount of packets that are transmitted or received Yellow Blinking Data collision is occurring on the port The...

Страница 17: ...d AUTO toggle switches to set 10 100 Mbps ports 17 and 18 for full or auto duplex mode 3 Fans 4 AC power outlet Figure 2 5 Rear panel of the Model SW518 switch 595EA 1 FDX HDX 8 10 Mbps 9 10 FDX AUTO...

Страница 18: ...this mode the 10 100 Mbps port operates in either full or half duplex mode depending on the operating mode of the remote port If the remote port cannot provide the proper signal to indicate its own c...

Страница 19: ...us configurations The configuration examples in this chapter illustrate the integration of the switch in network environments of all sizes and types These examples include a network of a few workstati...

Страница 20: ...network into a single efficient bridged node increasing overall bandwidth and throughput Segments attached to the switching hub do not have to cross the backbone They can now reach each other at near...

Страница 21: ...lso be used 4 Model EN516 Ethernet hubs Normal Uplink push button set to Uplink position 5 Server with 10 Mbps connection 6 PCs with 10 Mbps connection 7 PCs with 100 Mbps connection Figure 3 2 Model...

Страница 22: ...ers The users who require more power are networked to the NETGEAR FE516 Fast Ethernet hubs Key 1 Model SW518 Ethernet switch Normal Uplink push button to configure port 18 set to Uplink position Norma...

Страница 23: ...of the switch as described in Appendix A Technical Specifications Package Contents Unpack the contents of the package and verify them against the following list Model SW510 or Model SW518 switch Self...

Страница 24: ...rical outlet 3 Proceed to Installing the Switch on a Flat Surface or Installing the Switch in a Rack Installing the Switch on a Flat Surface To install the switch on a desktop or any other flat surfac...

Страница 25: ...these steps 1 Attach the mounting brackets to the sides of the switch as illustrated in Figure 4 1 Hold a mounting bracket against each side of the switch and align the countersunk screw holes in the...

Страница 26: ...Uplink push button eliminates the need to use a crossover cable when connecting similarly wired devices Ports 8 and 10 on the Model SW510 switch and ports 16 and 18 on the Model SW518 switch can be c...

Страница 27: ...must be set to FDX if you are connecting to legacy full duplex 100 Mbps devices that do not generate signals indicating duplex mode If the duplex switch is set to AUTO mode when connecting to legacy...

Страница 28: ...erify network communications by ensuring that all the necessary connections have been made that all connected resources can be accessed and that the LED indicators on the switch are functioning proper...

Страница 29: ...ix C Ethernet and Cabling Guidelines for additional information on twisted pair or straight through cable use HDX FDX AUTO Duplex Toggle Switches The factory setting for the duplex toggle switches on...

Страница 30: ...nected Network Adapter Cards Make sure the network adapter cards installed in the PCs are in working condition Configuration If problems occur after altering the network configuration restore the orig...

Страница 31: ...5 IEEE 802 3u 100BASE TX Data Rate 10 Mbps differential Manchester encoded IEEE 802 3 100 Mbps with 4B 5B encoding and MLT 3 physical interface for 100BASE TX Interface RJ 45 connector Specifications...

Страница 32: ...e altitude 10 000 ft 3 000 m maximum Electromagnetic Emissions Meets requirements of CE mark commercial FCC Part 15 Subpart B Class A EN 55 022 CISPR 22 Class A VCCI Class 1 Electromagnetic Susceptibi...

Страница 33: ...d rate 14 800 frames second maximum on 10 Mbps port 148 000 frames second maximum on 100 Mbps port Network latency Less than 75 microseconds for 64 byte frames in store and forward mode Address databa...

Страница 34: ...SW510 bk Page 4 Wednesday March 12 1997 10 49 AM...

Страница 35: ...r shielded 100 twisted pair cable and connects into the vista RJ 45 connector The vista RJ 45 connector also referred to as a 10 Mbps or 10 100 Mbps port is used to connect stations hubs and switches...

Страница 36: ...RJ 45 connector Table 5 1 Pin assignments for the RJ 45 plug and vista RJ 45 connector Pin Normal assignment Uplink assignment 1 Input Receive Data Output Transmit Data 2 Input Receive Data Output Tr...

Страница 37: ...e 100BASE TX Fast Ethernet technology maintains the same concepts as the 10BASE T technology Both use the same Carrier Sense Multiple Access with Collision Detection CSMA CD and Media Access Control M...

Страница 38: ...are media dependent interfaces with crossover ports referred to as MDI X or Normal ports Computer ports and PC adapter card ports are usually media dependent interface ports referred to as MDI or Upli...

Страница 39: ...B Normal or MDI X port as on a hub or switch 1 2 3 6 Pin numbers Figure 5 1 Straight through twisted pair cable Figure 6 2 illustrates crossover twisted pair cable Key A and B Normal or MDI X port as...

Страница 40: ...SW510 bk Page 4 Wednesday March 12 1997 10 49 AM...

Страница 41: ...C 3 specifications C 2 straight through twisted pair 4 4 C 3 troubleshooting 5 2 twisted pair C 2 Collision LED 2 1 2 4 connections to other devices 4 4 to PCs 2 2 to servers 2 2 crossover twisted pa...

Страница 42: ...ton 2 1 3 2 4 4 P package contents 4 1 ports 10 Mbps 1 2 2 1 3 1 4 5 100 Mbps 2 4 3 2 10 100 Mbps 1 3 2 2 2 6 4 5 Power LED 2 1 protocols C 1 R rear panel Model SW510 switch 2 5 Model SW518 switch 2 5...

Отзывы: