Physical Description
2-5
Table 2-2. Port status LEDs
Label
Color
Activity
Function
Collision
Orange
Blinking light
Indicates collision during packet transmission on the port.
Transmit
Green
Blinking light
Indicates packet transmission on the port.
Receive
Green
Blinking light
Indicates packets are being received on the port.
Link
Green
Steady light
Indicates a valid link is established on this port.
Light off
No valid link is established on this port. For troubleshooting
procedures, refer to Appendix D, “Troubleshooting.”
100M
Green
Steady light
Port is operating at 100 Mbps.
Light off
Port is operating at 10 Mbps.
Diagnostics Push Button
The Diagnostics push button initiates the self-diagnostics test to determine the status of the system
components of the switch. The diagnostic test will automatically start when the system is powered on.
To start the diagnostic test after the switch has started operation, press the Diagnostics push button for
two seconds and then release.
After the self-diagnostic test starts, it will continue until all of the components of the ports are tested.
On completion of the diagnostic testing process, the LEDs will continue to blink (refer to Table 2-3).
This blinking indicates the corresponding port components that have failed. The blinking will
continue until the failed port has been repaired.
Table 2-3. Port Diagnostic Test
LED Label
Color
Activity
Diagnostic Display Mode
Collision
Orange
Blinking light
Failed port I.C. test.
Transmit
Green
Blinking light
Failed output queue RAM test.
Receive
Green
Blinking light
Failed input queue RAM test.
Link
Green
Blinking light
Failed routing table RAM test.