Automatic address learning function to build the packet-forwarding information
table. The table contains up to 32K Media Access Control (MAC) addresses.

Store-and-forward transmission to remove bad packets from the network.

Active flow control to minimize packet loss and frame drops.

Half-duplex backpressure control.

Per-port status LEDs and system status LEDs.

NETGEAR green power-saving features:

-

Energy efficiency mode that fully conforms to the IEEE802.3az standard

-

Per-port automatic change to a lower power mode when the port link is down

Safety instructions and warnings

Use the following safety guidelines to ensure your own personal safety and to help
protect your system from potential damage.

To reduce the risk of bodily injury, electrical shock, fire, and damage to the equipment,
observe the following precautions:

This product is designed for indoor use only in a temperature-controlled and
humidity-controlled environment. Note the following:

-

For more information about the environment in which this product must operate,
see the environmental specifications in the appendix or the data sheet.

-

If you want to connect the product to a device located outdoors, the outdoor
device must be properly grounded and surge protected, and you must install an
Ethernet surge protector inline between the indoor product and the outdoor
device. Failure to do so can damage the product.

-

Before connecting the product to outdoor cables or devices, see
https://kb.netgear.com/000057103 for additional safety and warranty information.

Failure to follow these guidelines can result in damage to your NETGEAR product,
which might not be covered by NETGEAR’s warranty, to the extent permissible by
applicable law.

Observe and follow service markings:

-

Do not service any product except as explained in your product documentation.
Some devices should never be opened.

-

If applicable to your product, opening or removing covers that are marked with
the triangular symbol with a lightning bolt can expose you to electrical shock.

Hardware Installation Guide

8

Introduction

8-Port Multi-Gigabit/10G Ethernet (Ultra60 PoE++) Smart Managed Pro Switch with 2 SFP+ Ports

Содержание MS510TXM

Страница 1: ...stallation Guide 8 Port Multi Gigabit 10G Ethernet Ultra60 PoE Smart Managed Pro Switch with 2 SFP Ports Models MS510TXM MS510TXUP NETGEAR Inc 350 E Plumeria Drive January 2021 San Jose CA 95134 USA 2...

Страница 2: ...the regulatory compliance document before connecting the power supply For NETGEAR s Privacy Policy visit https www netgear com about privacy policy By using this device you are agreeing to NETGEAR s...

Страница 3: ...vity 17 Transceiver modules and cables for SFP fiber ports 18 Multi function Reset button 18 PoE port capacities and budget for model MS510TXUP 19 Chapter 3 Applications Multispeed PoE and PoE access...

Страница 4: ...ep 9 Manage the switch 32 Chapter 5 Troubleshooting Troubleshooting chart 36 PoE troubleshooting suggestions 37 Additional troubleshooting suggestions 38 4 8 Port Multi Gigabit 10G Ethernet Ultra60 Po...

Страница 5: ...del MS510TXUP can provide Ultra60 PoE 802 3bt on its eight multispeed copper ports so that you can let the switch deliver power to PoE devices such as WiFi 6 access points security cameras PoE speaker...

Страница 6: ...ipment room The switch is IEEE compliant and offers low latency All ports can automatically negotiate to the highest speed which makes the switch very suitable for a mixed environment with multispeed...

Страница 7: ...over fiber 10GBASE SR 10GBASE LR IEEE 802 3ab 1000BASE T IEEE 802 3i 10BASE T IEEE 802 1Q VLAN tagging IEEE 802 3x Full duplex flow control IEEE 802 3ad Link aggregation LAG with LACP IEEE 802 1ab LL...

Страница 8: ...ation about the environment in which this product must operate see the environmental specifications in the appendix or the data sheet If you want to connect the product to a device located outdoors th...

Страница 9: ...electric shock by shorting out interior components Use the product only with approved equipment If applicable to your product allow the product to cool before removing covers or touching internal comp...

Страница 10: ...roper grounding Do not use adapter plugs or remove the grounding prong from a cable If you must use an extension cable use a three wire cable with properly grounded plugs Observe extension cable and p...

Страница 11: ...e Overview This chapter describes the switch hardware features The chapter includes the following sections Hardware overview of model MS510TXM Hardware overview of model MS510TXUP Switch hardware inte...

Страница 12: ...ts that also support 100 1000BASE T Each port provides a left LED that functions as the combined link speed and activity LED The port does not provide a right LED For more information about the LEDs s...

Страница 13: ...established Blinking yellow The port is transmitting or receiving packets at 100 Mbps or 1000 Mbps Ports 1 4 left LEDs Link speed and activity Off No link is established Solid green A valid link at a...

Страница 14: ...E ports Front panel model MS510TXUP The following figure shows the front panel of model MS510TXUP Figure 3 Front panel model MS510TXUP The following table describes the components on the front panel f...

Страница 15: ...speed and activity LED For more information about the LEDs see LEDs model MS510TXUP on page 15 Ports 9F and 10F LEDs model MS510TXUP The following table describes the LEDs on the front panel of model...

Страница 16: ...ckets at 5 Gbps 2 5 Gbps 1000 Mbps or 100 Mbps Ports 5 8 left LEDs Link speed and activity Off The port is not delivering PoE Solid green The port is delivering PoE Solid yellow A PoE fault occurred F...

Страница 17: ...ategory 6e Cat 6e To simplify the procedure for attaching devices all RJ 45 ports support Auto Uplink technology This technology allows attaching devices to the RJ 45 ports with either straight throug...

Страница 18: ...ansceiver 10GBASE LR Lite SFP single mode LC GBIC Gigabit transceiver modules AGM734 SFP transceiver 1000BASE T SFP copper RJ 45 GBIC Direct attach cables AXC761 SFP 1 m about 3 3 ft direct attach cab...

Страница 19: ...set the switch to factory default settings and reset the registration status Press the Reset button for more than 10 seconds During the restart or reset process the Power LED lights yellow PoE port ca...

Страница 20: ...High power PoE and PoE 4 25 5W 40 0W 45 0W Ultra high power PoE 5 40 0W 51 0W 60 0W Ultra high power PoE 6 The previous table shows the standard power ranges calculated with the maximum cable length o...

Страница 21: ...nnections This chapter shows application examples with 10G 5G 2 5G and 1G connections and for model MS510TXUP multispeed PoE connections The chapter includes the following sections Multispeed PoE and...

Страница 22: ...ispeed PoE and PoE access points and cameras Table 7 Line colors in the figure Description Line Color PoE 802 3bt connection for example to a PoE WiFi 6 access point Blue PoE 802 3at connection for ex...

Страница 23: ...ive simultaneously when the devices correctly report their PoE class to the switch Multispeed backbone switching You can use the switch as a multispeed backbone switch in a network that serves network...

Страница 24: ...system consists of one switch one server and one storage platform Both systems toghether provide full data redundancy with exact replication 10G 10G 10G 10G 10G 10G 10G 10G Figure 7 High speed network...

Страница 25: ...e following sections Step 1 Prepare the site Step 2 Protect against electrostatic discharge Step 3 Unpack the switch Step 4 Install the switch Optional Step 5 Install an SFP transceiver module or cabl...

Страница 26: ...e Install the switch in a dry area with an ambient temperature between 32 F and 122 F 0 C and 50 C Keep the switch away from heat sources such as direct sunlight warm air exhausts hot air vents and he...

Страница 27: ...tistatic floor pads workbench pads and an antistatic grounding strap Step 3 Unpack the switch The following figure shows the package contents Figure 8 Switch package contents Check the contents of the...

Страница 28: ...AR reseller for replacement Step 4 Install the switch You can install the switch in a standard 19 inch 48 26 centimeter network equipment rack or on a flat surface Install the switch in a rack To inst...

Страница 29: ...en stacked switches Optional Step 5 Install an SFP transceiver module or cable For more information about transceiver moduels and direct attach cables DACs see Transceiver modules and cables for SFP f...

Страница 30: ...stall an Ethernet surge protector inline between the switch and the outdoor device Failure to do so can damage the switch Note Before connecting this switch to outdoor cables or devices see https kb n...

Страница 31: ...45 Ethernet ports on the switch 3 Verify that all cables are installed correctly Step 7 Check the installation Before you apply power to the switch perform the following steps To check the installati...

Страница 32: ...e switch which results in the improvement of its overall performance as well as the performance of the network Note By default the DHCP client of the switch is enabled If the switch cannot get an IP a...

Страница 33: ...ice UI Note the following about changing the management mode Changing to NETGEAR Insight Mobile App and Insight Cloud Portal mode The first time that you change to this mode the switch is set to facto...

Страница 34: ...g the Directly Connect to Web Browser Interface management mode are not saved to the cloud server Hardware Installation Guide 34 Installation 8 Port Multi Gigabit 10G Ethernet Ultra60 PoE Smart Manage...

Страница 35: ...oting This chapter provides information about troubleshooting the switch The chapter includes the following sections Troubleshooting chart PoE troubleshooting suggestions Additional troubleshooting su...

Страница 36: ...ts from any networked device to any other networked device After you connect to the switch device UI you can configure the Spanning Tree Protocol STP to prevent network loops One possible cause is tha...

Страница 37: ...wing table Table 10 PoE fault conditions and possible solutions Possible Solution PoE Fault Condition The problem is most likely with the attached PD Check the condition of the PD or restart the PD by...

Страница 38: ...tch integrity If necessary verify the integrity of the switch by restarting it To restart the switch disconnect the power from the switch and then reconnect the power If the problem continues contact...

Отзывы: