Installation Guide

3.  Connect devices to the switch. 

We recommend using the following cables and SFP modules: 
•  Use a Category 5e (Cat 5e), Category 6 (Cat 6), or Category 6a (Cat 6a) 

cable a for copper port at 1/2.5/5 Gbps.

• 

Use a NETGEAR AGM731F or AGM732F for a fiber port at 1 Gbps.

• 

Use a NETGEAR AXM761, AXM762, or AXM764 for a fiber port at 10 Gpbs.

• 

Use a NETGEAR AXC761 (1 m) or AXC763 (3 m) cable for a fiber port.

Note: 

If purchased, SFP modules and cables are shipped separately. For more 

information about installing an SFP module, see the hardware installation guide.

2. Perform the initial configuration

You can manage your switch through its web management interface or by using 
the command-line interface (CLI) through a console port. This guide shows you 

how to configure your switch using the web management interface. It also covers 
how to use the CLI to determine a DHCP-assigned IP address or using ezconfig 

to assign a static IP address. For more information about CLI management,  visit 

https://www.netgear.com/support/

 to download the CLI reference manual and 

software administration guide.

To use web management to configure your switch, use one of the following 

procedures, depending on how your Windows computer is set up:

•  Computer in DHCP client mode without a DHCP server.
•  Computer with a static IP address.
•  Computer in DHCP client mode with DHCP server.

Computer in DHCP client mode without a DHCP server

The switch assumes a default IP address of 169.254.100.100 and a subnet mask 
of 255.255.0.0. The switch is in the same subnet used by the computer NIC port 

when in DHCP-client mode without a DHCP server present. Use this IP value to 
log in to the switch. 

Computer with a static IP address

When the computer is in this mode, the switch must also be assigned a static 

IP address. To assign a static IP address, connect a VT100/ANSI terminal or a 
workstation to one of the switch’s console ports. A cable for the mini USB port 

and a straight-through RJ-45 cable are supplied. 

NETGEAR ProSAFE Managed Switches

M5300 Series

1. Set up the switch

Prepare the installation site so that mounting, access, power source, and 
environmental requirements are met. For more information about these 
requirements, visit

 https://www.netgear.com/support/

 to download the hardware 

installation guide.

1.  Install the switch using one of the following methods:

• 

On a flat surface.

 Attach one of the rubber footpads that came with the 

switch on each of the four concave spaces on the bottom of the switch.

• 

In a rack.

 Use the rack-mount kit that is supplied with your switch, 

following the installation instructions in the hardware installation guide.

2.  Apply AC power.

The Power LED lights solid yellow while the switch conducts a power-on self-
test (POST). After the switch passes the POST, the Power LED lights solid green, 
and the switch is functional. If the Power LED does not light green, see the 
following troubleshooting tips:
•  If the POST fails, the Power LED remains solid yellow. See the 

troubleshooting section of the hardware installation guide for more 
information.

• 

If the Power LED does not light at all, check to see that the power cable is 

plugged in correctly and that the power source is functioning. If this action 
does not resolve the problem, see the troubleshooting section of the 
hardware installation guide for more information.

To configure the switch:

1.  Start a terminal emulation program (TEP):

• 

Windows XP or earlier.

 Use HyperTerminal. 

• 

Windows Vista or later.

 Use a TEP from the Internet.

• 

Macintosh.

 Use ZTerm.

• 

UNIX

. Use a terminal emulator such as TIP.

2.  Select a console port using the console switch on the rear panel:

• 

Mini USB port

 (cable included).

Note: 

You might need to install the USB serial port driver before you can 

use the USB port on the computer to connect to the switch. To download 
the USB driver, visit 

https://www.netgear.com/support/

, enter your 

model number in the search box, and click the Downloads button on the 

product page.

• 

DB9 

(cable not included).

3. 

Configure the TEP with the following settings (written below the connector 

on the switch front panel):

• 

Baud rate

. 115200 bps

• 

Data bits

. 8

• 

Parity

. none

• 

Stop bit

. 1

• 

Flow control

. none

4.  At the user prompt, log in to the switch using the user name 

admin

 and 

press Enter. 

5.  At the password prompt, press Enter again (no password is needed for initial 

configuration).

6.  At the next command prompt, type 

ezconfig

 and press Enter.

The ezconfig utility is now running in the switch. 

7. 

Set a static IP address and subnet mask using the ezconfig utility as shown in 

the following example. 

 

Netgear Switch) #ezconfig

  EZ Configuration Utility

Make sure that the switch IP address is in the same subnet as the computer.