NETGEAR GSM7328FS - ProSafe Switch - Stackable Скачать руководство пользователя страница 2

Publication Version 1.0, March 2006

© 2006 by NETGEAR, Inc. All rights reserved. Information is subject to change without notice. 

Trademarks

The Netgear Logo, the Gear Guy, Everybody’s connecting, and ProSafe are trademarks or registered trademark of 
Netgear, Inc. in the United States and other countries. Microsoft, Windows, and the Windows logo are trademarks or 
registered   trademarks of Microsoft Corporation in the United States and/or other countries. Other brand and product 
names are trademarks or registered trademarks of their respective holders. 

Statement of Conditions

In the interest of improving internal design, operational function, and/or reliability, NETGEAR reserves the right to 
make changes to the products described in this document without notice.

NETGEAR does not assume any liability that may occur due to the use or application of the product(s) or circuit 
layout(s) described herein.

Certificate of the Manufacturer/Importer

It is hereby certified that the NETGEAR ProSafe 24-Port 10/100/1000 L3 managed Stackable Switch with 4 High-speed 
I/O Module Bays GSM7328S has been suppressed in accordance with the conditions set out in the BMPT-AmtsblVfg 
243/1991 and Vfg 46/1992.The operation of some equipment (for example, test transmitters) in accordance with the 
regulations may, however, be subject to certain restrictions. Please refer to the notes in the operating instructions. 

It is hereby certified that the NETGEAR ProSafe 48-Port 10/100/1000 L3 managed Stackable Switch with 4 High-speed 
Module Bays GSM7352S has been suppressed in accordance with the conditions set out in the BMPT-AmtsblVfg 243/
1991 and Vfg 46/1992.The operation of some equipment (for example, test transmitters) in accordance with the 
regulations may, however, be subject to certain restrictions. Please refer to the notes in the operating instructions. 

Federal Office for Telecommunications Approvals has been notified of the placing of this equipment on the market and 
has been granted the right to test the series for compliance with the regulations. 

Voluntary Control Council for Interference (VCCI) Statement

This is Class A product based on the standard of the Voluntary Control Council for Interference by Information 
Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio interference may occur, in 
which case, the user may be required to take corrective actions.”

Federal Communications Commission (FCC) Compliance Notice: Radio Frequency Notice 

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 

This device may not cause harmful interference. 

This device must accept any interference received, including interference that may cause undesired operation. 

Note:

 This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 

15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a 
residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and 
used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no 
guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to 

Содержание GSM7328FS - ProSafe Switch - Stackable

Страница 1: ...201 10813 01 March 2006 NETGEAR Inc 4500 Great America Parkway Santa Clara CA 95054 USA Managed Stackable Layer 3 Switches GSM7328S and GSM7352S Hardware Installation Guide...

Страница 2: ...with the conditions set out in the BMPT AmtsblVfg 243 1991 and Vfg 46 1992 The operation of some equipment for example test transmitters in accordance with the regulations may however be subject to ce...

Страница 3: ...e du minist re des Communications du Canada Cet appareil num rique NETGEAR ProSafe 48 Port 10 100 1000 L3 managed Stackable Switch with 4 High speed Module Bays GSM7352S respecte les limites de bruits...

Страница 4: ...wser such as Internet Explorer or Netscape are required Product and Publication Details Warning This is a Class A product In a domestic environment this product may cause radio interference in which c...

Страница 5: ...ructions 2 7 Chapter 3 Hardware Installation Package Contents 3 1 Protecting Against Electrostatic Discharge 3 2 Unpacking the Hardware 3 2 Installation 3 3 Select a Location 3 4 Install the Switch 3...

Страница 6: ...ion Version 1 0 March 2006 ii Chapter 4 Troubleshooting Troubleshooting Chart 4 1 Additional Troubleshooting Suggestions 4 2 Appendix A Technical Specifications A1 Appendix B Default Configuration Set...

Страница 7: ...concepts and terminology This guide uses the following typographical conventions This guide uses the following formats to highlight special messages Table 1 1 Typographical Conventions Italics Emphas...

Страница 8: ...Danger This is a safety warning Failure to take heed of this notice may result in personal injury or death Table 1 2 Manual Scope Product Version ProSafe 24 Port 10 100 L3 managed Stackable Switch wit...

Страница 9: ...TGEAR switches ProSafe 48 Port 10 100 1000 L3 managed Stackable Switch with 4 High speed Module Bays GSM7352S ProSafe 48 Port 10 100 1000 L3 managed Stackable Switch with 4 High speed Module Bays GSM7...

Страница 10: ...witches Off Switch acts as a slave unit in a stack of GSM7300S switches RPS redundant power supply Solid green The redundant power supply is connected and using internal power Solid yellow The switch...

Страница 11: ...orts 2 LEDs per port Link ACT LED Off No link is established on the port Solid green A valid link is established on the port Blinking green The port is sending or receiving packets SPD LED Off No link...

Страница 12: ...module bays support any combination of either the ProSafe 10 Gigabit Ethernet XFP Adapter AX741 or the ProSafe 24 Gigabit Stackable Module AX742 GSM7352S Front Panel and LEDs The figure below shows t...

Страница 13: ...roviding power to the switch Blinking yellow The redundant power supply unit is present but the power has failed Off The redundant power supply is disconnected or not present Fan Red Fan has failed Of...

Страница 14: ...LED XFP Module present LED ACT Off The 10GbE Adapter is not present Solid green The 10GbE Adapter is present Blinking green Packets transmission or reception is occurring on the port Stacking Adapter...

Страница 15: ...provider The power cable extension cable or plug is damaged An object has fallen into the product The product has been exposed to water The product has been dropped or damaged The product does not ope...

Страница 16: ...arked on the product To help prevent electric shock plug the system and peripheral power cables into properly grounded electrical outlets The peripheral power cables are equipped with three prong plug...

Страница 17: ...dapter cord Rubber footpads for tabletop installation Rubber caps for the SFP sockets Rack mounting kit Null modem serial cable RS 232 with 9 pin connectors NETGEAR CD The CD contains Configuration so...

Страница 18: ...nts in a static safe area If possible use antistatic floor pads workbench pads and an antistatic grounding strap Unpacking the Hardware Check the contents of the boxes to make sure that all items are...

Страница 19: ...age immediately Installation Install the equipment in the sequence presented in this chapter as shown below 1 Select a Location See Select a Location on page 3 4 2 Install the Switch See Install the S...

Страница 20: ...r source within 6 feet 1 8 meters of the installation location Power specifications for the switch are shown in Appendix A Technical Specifications Be sure that the AC outlet is not controlled by a wa...

Страница 21: ...r footpad on each of the four concave spaces on the bottom of the switch The rubber footpads cushion the switch against shock and vibrations Installing the Switch in a Rack To install the switch in a...

Страница 22: ...switch The only way to apply or remove power is to connect or disconnect the power cord Before you connect the power cord select an AC outlet that is not controlled by a wall switch which can turn off...

Страница 23: ...hernet XFP Adapters AX741 The modules and adapters are sold separately SPF Modules The module bay accommodates a standard SFP module with an LC connector that is compatible with the IEEE 802 3z 1000BA...

Страница 24: ...tallation The High Speed I O Module Bays support ProSafe 10 Gigabit Ethernet XFP Adapter AX741 or ProSafe 24 Gigabit Stackable Modules AX742 When the ProSafe 10 Gigabit Ethernet XFP Adapter AX741 is i...

Страница 25: ...or the rear of each switch 2 Connect the provided stacking cable between a pair of AX742 modules in each switch within a stack 3 Connect each switch to the next in a cascade to build the backplane of...

Страница 26: ...e switch When the power is off you can remove the cover plate and connect the RPS unit to the switch After all connections are completed apply power to the switch Connecting Equipment to the Switch Yo...

Страница 27: ...or UNIX workstation Null modem cable with 9 pin connectors on each end shipped with the product To connect a console to the switch 1 Connect the null modem cable to the console port on the rear of th...

Страница 28: ...his purpose Quick Install Guide Explains basic setup and configuration provided as both a print document and in PDF format on the NETGEAR CD Command Line Interface Reference for the ProSafe 7300S Seri...

Страница 29: ...connection is not working Check the crimp on the connectors and make sure that the plug is properly inserted and locked into the port at both the switch and the connecting device Make sure that all c...

Страница 30: ...installation do not exceed the Ethernet limitations Switch Integrity You can verify the integrity of the switch by resetting the switch To reset the switch use the Tools Reset command or remove AC po...

Страница 31: ...tiate the correct duplex mode and speed if the device at the other end of the link supports auto negotiation If the device does not support auto negotiation the switch only determines the speed correc...

Страница 32: ...Managed Stackable Layer 3 Switches GSM7328S and GSM7352S Hardware Installation Guide 4 4 Troubleshooting v1 0 March 2006...

Страница 33: ...ASE SR 802 3x flow control Switch management Port mirroring support SNMP v1 v2c v3 RFC1757 RMON 1 groups 1 2 3 and 9 RFC1213 MIB II RFC1643 Ethernet Interface MIB RFC1493 bridge MIB RFC2131 DHCP clien...

Страница 34: ...tors for 10BASE T 100BASE TX and 1000BASE T Eight slots are gigabit interface converters SFP for SFP modules Four I O module bays for either 10 Gigabit Ethernet or 24 Gigabit stacking connectivity RS...

Страница 35: ...humidity noncondensing Storage humidity 95 maximum relative humidity noncondensing Operating altitude 10 000 ft 3 000 m maximum Storage altitude 10 000 ft 3 000 m maximum Electromagnetic emissions an...

Страница 36: ...Managed Stackable Layer 3 Switches GSM7328S and GSM7352S Hardware Installation Guide A 4 Technical Specifications v1 0 March 2006...

Страница 37: ...ed Flow control full duplex Disabled Broadcast storm control Enabled Gigabit port type Auto detect Management IP configuration DHCP Password protection Disabled User name Admin Password none Web acces...

Страница 38: ...arch 2006 IP routing Disabled RIP Disabled MAC address aging 300 seconds OSPF Disabled SNMP community public read only access private read write access DHCP Server Disabled VLAN Ingress filtering Enab...

Страница 39: ......

Страница 40: ...NETGEAR Inc 4500 Great America Parkway Santa Clara CA 95054 USA March 2006...

Отзывы: