For additional configurations, see 

HELPFUL LINKS

.

Connect power cords

Connect controller to computer

Connect controller to networks 

Controller

Two power supplies MUST be

installed in each controller chassis.
-  Ensure the power switch 

on each power supply is in

the OFF position (O).

-  Cable both power supplies 

for each controller chassis.  

CAUTION

PRUDENCE

CAUTION

PRUDEN

CE

AT

TE

NTIO

N

IN

SE
R

T

P

S

U

BL

A

N

K

IN

SL

O

TS

2

O

R

3

CAUT

ION

PRUD

ENC

E

CAUTION

PRUDENCE

ATT

E

NT

IO

N

IN

SE

R

T

P

S

U

BL

ANK

IN

S

LO

TS

2

O

R

3

4

2

3

1

4

2

3

1

4

2

3

1

4

2

3

1

LNK

LNK

IOM6

IO

M6

LNK

LNK

IOM6

IO

M6

Power switch

Power switch

Use
retaining clips

X20 6 7

X3 149A

1

3

4

e i

0

e j

0

e k

0

e i

0

3

4

2

LNK

a

0

b

0

c

0

d

0

LNK

LNK

LNK

0a

e

e0b

e0c

e0d

LNK

LNK

LNK

LNK

LNK

LNK

LNK

LNK

0e|0e

e

0f|0f

e

0g|0g

e

0h|0h

e

Disk shelf

Two power supplies

MUST be installed in

each disk shelf.
-  Ensure the power

switch on each power

supplyis in the OFF

position (O).

-  Cable both power

supplies for each disk shelf.

DO NOT power on the controller at this point.

Note that different clients may have different connection settings. 

For example, on a PuTTY connection, set the keyboard to VT100+, 

flow control to OFF, and baud rate to 9600.

• Connect the management port (wrench icon) on

your controller to the Ethernet switch in your man-

agement network, using a network cable.

See your network administrator for help connecting
to your switches.

• Connect 10GigE ports or GigE ports

for data connection.

The serial console is needed to configure a management IP address 

for the AltaVault appliance, using a client. Once this is done, further 

configuration can be done using a Web browser and connecting to 

the management IP address. 

Connect controller to shelf

For optimal system performance, use one of the supported cable configurations displayed below.
• Configure up to three shelves with the AVA400 model
• Configure up to four shelves with the AVA800 model

Altavault systems support controller to shelf cables

 

(with mini SAS/QSFP connectors)

 

and shelf to shelf cables 

(QSFP/QSFP connectors)

.

LNK

0h|0h

e

3

4

e i

0

e j

0

e k

0

e i

0

AltaVault system

Console port 

RJ45 serial adapter

Extension serial cable 
to USB connection.

Client

AVA400/AVA800: 1 Shelf

Push all cable ends in 

until you hear CLICK.

MINI

Latch release

faces 

down

 

on disk shelf 

SAS ports

Cable controller to shelf ports.

Cable shelf to shelf ports.

mini SAS HD-QSFP cable

1

QSFP-QSFP cable

2

MINI

Shelf 1

ID 00

Controller

AVA400/AVA800: 2 Shelves

MINI

MINI

Shelf 1

ID 00

Shelf 2

ID 10

Controller

AVA400/AVA800: 3 Shelves

MINI

MINI

Shelf 1

ID 00

Shelf 3

ID 01

Controller

Shelf 2

ID 10

AVA800 only: 4 Shelves

MINI

MINI

Shelf 3

ID 01

Controller

Shelf 2

ID 10

Shelf 4

ID 11

Shelf 1

ID 00

GigE cable

To Ethernet switch

To management port 

(wrench icon) on controller 

3

4

e i

0

e j

0

e k

0

e l

0

2

4

6

8

1

3

5

7

10

12

14

16

9

11

13

15

12

11

14

13

16

15

6

5

8

7

10

9

2

1

4

3

1000/100/10M

LNK /

1000/100/10M

LNK /

To Ethernet switch 1

To host

LNK

LNK

LNK

LNK

e0a

e0b

e0c

e0d

10GigE cables

10GigE ports

GigE ports 

2

4

6

8

1

3

5

7

10

12

14

16

9

11

13

15

12

11

14

13

16

15

6

5

8

7

10

9

2

1

4

3

1000/100/10M

LNK /

1000/100/10M

LNK /

Install hardware 

|

 

2

Connect cables 

|

 

4

Install disk shelves 

|

 

3

NOTE:

 

Controller and disk shelves are shipped in separate boxes.

• Install the mounting rails (provided in rail kit) following the instructions in the rail kit.

- Use chassis handles while lifting.

• Mount the chassis in the rack.
• Secure chassis to rack using appropriate screws (not provided).
Alternatively, you can mid-mount the chassis using the mid-mount brackets provided in the rail kit.

For detailed rack installation instructions, see SAS Disk Shelves Installation and Service Guide for DS4243, DS2246, DS4486, and DS4246 on the NetApp Support site.

Install shelf in rack or cabinet

Refer to the the SAS Disk Shelves Installation and Service Guide for DS4243, DS2246, DS4486, and DS4246.

Optional 2-Post 

Mid-mount Brackets

Install controller in rack or cabinet

DO NOT remove HDDs from the disk shelf during installation. 

Excessive handling of the drives can lead to internal damage.

NOTE:

 

You can install the shelf below the controller. 

The distance between the shelf and controller is dependent on the length

of the SAS cables you plan to use.
• Install the mounting rails (provided in rail kit) following

the instructions in rail kit. Be cautious while lifting.

• Mount the disk shelf in the rack.
• Secure the shelf to the rack using the appropriate screws (not provided).

Install disk shelves in the order set at the factory. 
Each shelf is labeled with the associated controller serial number, loop or 

stack number of the shelf, and shelf serial number. The loop or stack number 

helps to identify the order of installation for each PCI slot on the controller. 

The root volume is labeled with loop or stack number 00, and is always the 

first shelf attached to the controller. The table shows the relationship of the 

controller and shelves for installation:

It is recommended to verify the shelf IDs prior fully cabling the system. 

To verify the IDs, attach a power cable to each shelf, power on the shelf, 

note the ID on the front panel, and power off each shelf.

Note: 

Additional shelves ordered from the factory have the shelf ID set to 00 but 

are not installed with the root volume. You must install additional shelves in the 

order listed in the table, and reset the shelf ID as described in Section 5.

LIFTING HAZARD

CAUTION

80-100 lbs. (36-45 kg)

3.0TB

3.0TB

3.0TB

3.0TB

3.0TB

3.0TB

3.0TB

3.0TB

3.0TB

3.0TB

3.0TB

3.0TB

3.0TB

3.0TB

3.0TB

3.0TB

3.0TB

3.0TB

3.0TB

3.0TB

3.0TB

3.0TB

3.0TB

3.0TB

Controller

PCI Slot

1
1

3
3

1

3
2

4

00

01
10

11

00

01
10

11

Loop or stack number 

on shelf label PCI Slot

Order of shelf

installation

Factory setting

shelf ID

DS4246

4.0TB

4.0TB

4.0TB

4.0TB

4.0TB

4.0TB

4.0TB

4.0TB

4.0TB

4.0TB

4.0TB

4.0TB

4.0TB

4.0TB

4.0TB

4.0TB

4.0TB

4.0TB

4.0TB

4.0TB

4.0TB

4.0TB

4.0TB

4.0TB

24 Disk drives

Right ear cover

Left ear cover

Shelf ID digital 

display (two digits)

Disk activity and fault LEDs 

Shelf LEDs:
      power
      shelf fault
      activity

CAUTION

PRUDENCE

CAUTION

PRUDE

NCE

AT

TENTI

O

N

IN

SER

T

P

S

U

B

LA

N

K

IN

S

LO
TS

2

O

R

3

CAUT

ION

PRUDENCE

CAUTION

PRUDENCE

A

TTE

NT

ION

INS

ERT

P

SU

BLANK

IN

SL

O

TS

2

O

R

3

4

2

3

1

4

2

3

1

4

2

3

1

4

2

3

1

LNK

LNK

IOM6

IO

M6

LNK

LNK

IOM6

IO

M6

Two power supplies with integrated fans

DC fault

PSU ok

AC

Power supply LEDs :

AC fault

Fan fault

QSFP ports

QSFP port link LEDs

IOM fault LED

Two I/O modules (IOM6)

Bezel

Power LED

System 

attention LED

Controller

activity LED

A

A

N V

LNK

LNK

LNK

LNK

LNK

LNK

LNK

LNK

LNK

LNK

LNK

LNK

e0i

e0j

e0k

e0l

e0g 0g e0h 0h

e0f 0f

e0e 0e

e0d

e0c

e0b

e0a

0a

0b

0c

0d

1

2

3

4

REAR VIEW

Console port 

(Setting: 9600 N-8-1)

Management port

(wrench icon)

Controller 

attention LED

Power 

supplies 

RAID card with mini 

SAS HD ports (PCI 1)

RAID card with mini 

SAS HD ports (PCI 3)

FRONT VIEW

Not

used

Not

used

10 GigE 

ports

1 GigE 

ports

102 lbs. (46.3 kg)

Front view of disk shelf

A

Rear view of disk shelf

B

1

2

3

4