![Netafim NETAJET 4G Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/netafim/netajet-4g/netajet-4g_installation-manual_1669786016.webp)
16
NETAJET
™
4G
INSTALLATION MANUAL
DESCRIPTION
BP ST mode
Bypass system for storage-tank water source.
Operating principle:
For systems operating at low pressure - from an on-ground reservoir or a storage
tank [max. height: 6 meters (20 feet)].
The main line pump also serves as dosing booster pump.
Suitable for main line flow rate:
15-100 m³/h (66-440 GPM)
Flow limitation depends on the fertilizer injection rate and the size of the Venturis.
Suitable for main line pressure:
The water level in the storage tank should not be higher than 5 meters (16.4 feet) above the NetaJet™ 4G inlet.
Dosing channels:
Accommodates a wide variety of highly accurate dosing channels for fertilizer and concentrated/diluted acid:
•
Up to 5 x 50-600 l/hr (13-158 GPH)
•
Optional - Concentrated acid channel, 50 l/h (13 GPH)
Total fertilizer/acid suction capacity - up to 3000 l/h (792 GPH).
Controller:
NMC-Pro (Operation with third-party controllers is optional. Consult Netafim™.)
EC/pH:
Precise single or dual monitoring and control - selectable by customer.
Front view
Back view