TECHNICAL DATA
Performance
Nozzle
Working
pressure
(bar)
Flow
rate
(l/h)
Wetted
diameter*
(m)
Spacing (m x m)
Size
(mm)
Color
code
9 x 9
9 x 10
10 x 10
10 x 11
10 x 12
12 x 12
Precipitation (mm/h)
2.3
Gray
2.0
318
22
3.9
3.5
3.2
2.9
2.7
2.2
2.5
355
22
4.4
3.9
3.6
3.2
3.0
2.5
3.0
389
23
4.8
4.3
3.9
3.5
3.2
2.7
2.5
Purple
2.0
358
23
4.4
4.0
3.6
3.3
3.0
2.5
2.5
400
24
4.9
4.4
4.0
3.6
3.3
2.8
3.0
438
25
5.4
4.9
4.4
4.0
3.7
3.0
2.9
Orange
2.0
456
23
5.6
5.1
4.6
4.1
3.8
3.2
2.5
510
25
6.3
5.7
5.1
4.6
4.3
3.5
3.0
559
25
6.9
6.2
5.6
5.1
4.7
3.9
* Sprinkler head 0.5 meter above ground. At least 0.5 mm/h.
(a)
(b)
Sprinkler
Lateral
(a)
(b)
Sprinkler
Lateral
(a)
Sprinkler
Lateral
(b)
(b)
a = b
NOTE
The area-coverage and dispersion-uniformity of a layout of sprinklers is influenced by the alignment
of the sprinklers.
The common types of sprinkler alignment are:
Rectangular alignment
Triangular alignment
Isosceles
Equilateral
Do not confound isosceles with equilateral:
•
An isosceles triangle is a triangle in which two sides are of equal length. The distance between 2
adjacent sprinklers on the same lateral (a) is not equal to the distance between 2 sprinklers on
adjacent laterals. The height of the triangle represents the distance between adjacent laterals (b).
Isosceles is usually referred to In open-field applications.
•
An equilateral triangle is a triangle in which all three sides are equal. The distance between 2
adjacent sprinklers on the same lateral is equal to the distance between 2 sprinklers on adjacent
laterals. Equilateral is occasionally referred to in orchards due to the tree planting pattern.