14
NETBEAT
USER MANUAL
Battery In/input from solar panel (5VDC)
General description
Power
Battery operated - 3 x L92 ([email protected])
Inputs and outputs
Integrates digital,
analog and serial inputs,
with digital outputs
Up to 8 outputs for DC Latch valves
Up to 2 digital inputs for water meters, switches and condition triggers to dry contact
Up to 3 analog inputs for sensors (e.g. pressure sensor, tensiometer etc.)
2 serial ports for serial communication sensors (RS-232, SDI-12)
LED indicator
Bluetooth operation status
Enclosure
Robust UV stabilised enclosure rated to IP65
Operation temperature
-20ºC - 65ºC / -4ºF - 149ºF
Dimensions
215 x 160 x 40 mm / 8.5 x 1 ½ x 6”
Specifications
SYSTEM DESCRIPTION
NetBeat Remote Terminal Unit (NetRTU)
Transmits field data and activates remote system components such as field valves.
The NetRTU can also be used as a repeater* to extend communication range.
Features & benifits
Open unit for any input (sensors) or any output (valves, pumps, dosing)
Enables remote control of field devices.
Measures field parameters e.g. flow, pressure, soil moisture, plant and
weather station.
Managed by the NetMCU via radio using (LoRa) low power radio.
communication of up to 10km
with a clean line of sight (with repeaters).
Enables over-the-air maintenance and automatic firmware updates.
Various mounting options - on a wall, a pole or a rod.
Up to 3 years activation on one set of 3 batteries.
*A repeater consumes more energy since it is constantly active.
Do not use batteries. If an external power source is not
available a solar panel can be used to ensure
continuous operation (see
NetRTU
NetMCU
BT pairing button
(for RTU settings)
Status LED
Cable entry panel
Battery compartment
LoRa antenna
LoRa module