background image

NETBEAT

 

USER MANUAL 

V 001.01 - FEBRUARY 2019

Содержание 74700-000018

Страница 1: ...NETBEAT USER MANUAL V 001 01 FEBRUARY 2019...

Страница 2: ...S AND THE ASSOCIATED DOCUMENTATION THEY MAY STILL INCLUDE FAULTS NETAFIM WILL NOT ACCEPT RESPONSIBILITY FOR DAMAGE RESULTING FROM USE OF NETAFIM S PRODUCTS OR USE OF THIS MANUAL NETAFIM RESERVES THE R...

Страница 3: ...ntroller tile MCU AC DC DC latch tile MCU Analog In Tile NetBeat Remote Terminal Unit NetRTU Peripherals NetBeat sensors NetBeat NetRTU solar panel 4 4 4 5 5 5 5 5 5 6 6 6 7 8 8 8 9 10 11 11 12 13 13...

Страница 4: ...odily injury or direct damage to the crops the NetBeat system and or the infrastructure CAUTION The following text contains instructions aimed at preventing unwanted system operation installation or c...

Страница 5: ...Do not puncture the battery If a battery is found to be punctured take caution in handling the battery and avoid contact with the corrosive material in the battery All batteries can cause property da...

Страница 6: ...d supervised and carried out by competent trained and experienced personnel authorized by the local safety authority Make sure equipment used for work at height is certified by the local standards aut...

Страница 7: ...stem is well suited for the following applications Agricultural open field control systems including small farm to large scale agriculture projects utilizing drip and sprinklers or any other controlla...

Страница 8: ...f their hands allow growers to reduce water energy fertilizer costs Use crop models to optimize the use of resources More precise irrigation and nutrigation to increase crop yield and quality Optimize...

Страница 9: ...tRTU P S 1 P1 P2 MC1 P3 MV1 FB1 WM1 DU1 IV1 RT1 RT2 RT3 RT4 IV2 IV3 IV4 IV5 SM1 IV6 IV7 IV8 IV9 MV2 FB2 WM2 DU2 IV10 IV11 IV12 IV13 IV14 IV15 IV16 IV17 IV18 IV19 IV20 RT5 SM2 WM3 P PRS P PRS Pump room...

Страница 10: ...c Crop alerts Hydraulic system alerts Controls remote devices via radio and Single cable Works online or offline Enables remote over the air update and maintenance User friendly interface Hydraulic in...

Страница 11: ...sions 635 x 573 x 252 mm 25 x 22 9 16 x 10 MCU Power Tile The Power tile receives 12VDC input voltage from the Power Supply It supplies the voltage to all tiles and charges the backup battery with 12V...

Страница 12: ...915 433 MHz Output Power 14 20 dBm BW 125 250 500 kHz Spreading Factor 7 10 Cellular Parameter Rating Model Quectel UC20 G Frequency Bands UMTS 800 850 900 1900 2100 GSM 850 900 1800 1900 Output Powe...

Страница 13: ...nal voltage 1 2 1 V MCU Analog In Tile Serves mainly for external data input into the system Analog Channels Parameter Rating Number of analog inputs 6 Channel Type 5mV 15mV 0 10V 0 20mA Thermocouple...

Страница 14: ...es remote system components such as field valves The NetRTU can also be used as a repeater to extend communication range Features benifits Open unit for any input sensors or any output valves pumps do...

Страница 15: ...er RTU MCU Digital In Hydraulic sensors Water meter RTU MCU Digital In Fertilizer meter RTU MCU Digital In Pressure sensor RTU MCU Analog In General sensors General purpose sensor RTU MCU Analog In Ge...

Страница 16: ...t link to access NetBeat http netbeat netafim com In order to login you must have a pre defined Email address and password in the system If you don t have them contact the installer your sales manager...

Страница 17: ...Settings Farm Alerts Calendar view of the irrigation events Create and review irrigation programs Dashboard Map view of the farm Displays all the components that can be configured in the platform Ana...

Страница 18: ...Running Programs Alerts Alerts related to a technical malfunction or warning such as Low battery no communication with a remote unit etc Current conditions Hourly Forecast Irrigation Flow Rate Irrigat...

Страница 19: ...NETBEAT USER MANUAL 19 Widgets OPERATION Graph widget Gauge widget Reports widget Forecast widget...

Страница 20: ...20 NETBEAT USER MANUAL 2 Building Irrigation Program OPERATION Step 1 Add a new program Step 2 Choose a Mainline that the irrigation program is related to Add a new program...

Страница 21: ...d name the program and define its priority OPERATION High priority means that the program has a priority over the other programs and in case of a clash the high priority program will take place and st...

Страница 22: ...s OPERATION 1 2 3 1 Watering by duration Define the irrigation time duration 2 Watering by water depth Define the irrigation quantity by the mm or Inch units For this option the irrigated area should...

Страница 23: ...NETBEAT USER MANUAL 23 Step 5 not mandatory Configure the dosing OPERATION 2 Select recipe or create new one 1 Enable the dosing option 1 2...

Страница 24: ...Time Dosing system applies the fertilizers in pulses during the irrigation according to the time defined by the user Spread By Quantity Dosing system applies the fertilizers in pulses during the irrig...

Страница 25: ...NETBEAT USER MANUAL 25 Step 6 Configure the water distribution Where to irrigate OPERATION 1 Define the valves that are taking part in the program...

Страница 26: ...USER MANUAL OPERATION Step 6 Configure the water distribution Where to irrigate cont 2 Add a shift and name it Notice not to exceed the available capacity of the mainline 3 Define the relevant valves...

Страница 27: ...Define how to start the program based on daily irrigation weekly irrigation or by trigger 1 2 3 1 Daily irrigation Define the daily irrigation parameters 2 Weekly irrigation Define the weekly irrigati...

Страница 28: ...he irrigation program When to irrigate cont OPERATION When defined using time intervals the program will end according to time definitions Yet there is an option to end program using a trigger DP swit...

Страница 29: ...t OPERATION 3 Editing the program Step 2 Choose the segment you want to edit What When Where and click the Edit button Deletes the selected program Opens edit window for the selected section only Open...

Страница 30: ...Step 2 Manual operation If irrigation is not active at the moment click to activate irrigation Irrigation not active at the moment Irrigation active at the moment If irrigation is active at the momen...

Страница 31: ...e calendar is divided to columns based on configured mainlines OPERATION 5 Using the calendar Feedback from the field in real time Presents to the grower the field state at any given time Supports the...

Страница 32: ...ew measurements results from the field Analyze the data in order to make irrigation and Fertigation decisions Monitor the field on a daily basis Enable the grower to choose from a variety of measureme...

Страница 33: ...to locate gaps and take care of them Reports are only available from the computer and the tablet OPERATION Generate Report Parameters Analysis Section Alerts are sent in Real Time to mobile e mail tab...

Страница 34: ...34 NETBEAT USER MANUAL OPERATION NetBeat service includes the option to create as many users as you need and grant them access according to their roles 8 Quick tip User creation...

Страница 35: ...n the NetMCU with a 8mm flatbed screwdriver Visually inspect the NetMCU and the NetRTUs interior for Condensation Light to medium condensation can be addressed using silica gel packets consult the man...

Страница 36: ...Hz 5m 74740 000140 868 MHz 5m 74740 000145 915 MHz 5m 74740 000150 Description Cat No With display 220V 74700 000018 Without display 220V 74700 000019 With display 110V 74700 000020 Without display 11...

Страница 37: ...tenna cable 10m 33ft for NetMCU 74740 000111 NetBeat LoRa antenna cable 5m 15ft for NetRTU 74740 000114 Description Cat No NetMCU bus card 74720 000100 NetMCU LoRa module 74720 000101 NetMCU display 7...

Страница 38: ...n Licensee s use of toxic corrosive or caustic liquids and or gases with the Hardware exposure to severe weather conditions and water and to damage by animals vi any defect or problems caused by any d...

Страница 39: ......

Страница 40: ...GROW MORE WITH LESS WWW NETAFIM COM...

Отзывы: