Net2Edge LIB-225 Скачать руководство пользователя страница 9

 

 

 

Net2Edge

 | Liberator™ CE Quick Start Guide 

 

Once the new interface is set up, you will have to configure the port VLAN settings to complete 
the process. To do this you must go to 

Configuration > VLANs

 

 

 

 

 

For the management traffic the port you intend to use should be set to ‘

Access

’ – the 

‘Port VLAN’ field should contain the ID you set up under the IP interface. Please ensure 
that you add the VLAN ID to the ‘

Allowed Access VLANs

’ field at the top of the page 

 

In the event you are using Dual IP and have a separate IP interface set up for the CES 
traffic, you will need to set the  port you want to use to the following; 

o

 

Mode

: Trunk 

o

 

Port VLAN

: <ID you used to set up the IP interface> 

o

 

Port Type

: C-Port (can’t be changed under this Mode) 

o

 

Ingress Filtering

: Selected (can’t be changed under this Mode) 

o

 

Ingress Acceptance

: Tagged and Untagged (can’t be changed under this Mode) 

o

 

Egress Tagging

: Untag Port VLAN 

o

 

Allowed VLANs

: 1-4094 (this can be shortened to match your VLAN ID) 

 

Please note

: If you need to customise the port type or the Ingress filtering and acceptance, 

you can do so by setting the mode to ‘

Hybrid

’. 

 

4.3.

 

Setting up a logical link 

 

To use the Circuit Emulation features, the first setup step is to set up a logical link between a 
minimum of two PacketBand units – this link will carry the TDM data across a packet switching 
network. 
To do this you must go to the logical link sub menu which is located here

 

Configuration > CES > Link > Settings 

 

Содержание LIB-225

Страница 1: ...QSG Quick Start Guide LIB 225 Quick Start guide for Liberator CE ...

Страница 2: ... form or by any means graphic elec tronic or mechanical without written permission from Net2Edge The information contained herein is confidential property of Net2Edge Limited The use copy ing transfer or disclosure of such information is prohibited except by express written agree ment with Net2Edge Limited Revision History Rev Date Description A 1st July 2015 Initial Release B 6th April 2016 Re Br...

Страница 3: ...3 Features 4 4 Initial Configuration Setup 5 4 1 Local IP Address Subnet Mask Default Gateway 5 4 1 1 CLI Connection 5 4 1 2 Web UI Connection 6 4 2 Single IP vs Dual IP addressing 7 4 2 1 VLAN Settings 8 4 3 Setting up a logical link 9 4 4 Setting up the port and allocating channels 11 4 5 Clocking Configuration 12 5 Cable Pinouts 14 6 Contacts 17 ...

Страница 4: ...need to be configured in order to communicate and work with each other The setup requires a minimum of 2 units to set a communication link or Logical link as referred to in the units management menu 3 Features The Liberator has the following Hardware Features 3 x 1Gb packet ports front panel 2 x SFP cages front panel 1 x TDM port front panel 1 x Smart serial port front panel 1 x console port rear ...

Страница 5: ...eed this COM number for connecting to the box so it is advised you find this by going via the Control Panel Device manager menu on your machine computers running Windows only Next you will need to use terminal emulation software to connect to the units CLI interface this can be either HyperTerminal or PuTTY Once connected you will need to enter the default login details as below User admin Pwd bla...

Страница 6: ...me subnet as the Liberator CE then the browser should ask for login details Enter Admin as a username and leave the password blank to access the UI Once the management system has been accessed the unit s IP address subnet mask and gateway address can be changed by going to the following submenu Configuration System IP From there you can modify the IP details please note that if you change the IP a...

Страница 7: ...ss you can enter your preferred IP for the TDM data traffic to use this should also be followed with the subnet mask length under the IPv4 prefix Please note If you are going to use the Single IP set up then you should do the following o The Local IPv4 address must be the same as the management IP you are using o Allow Management on CES IP should be set to Yes If you are going to use the Dual IP s...

Страница 8: ...o if you are not planning on using VLAN 1 then you will need to set up a different VLAN interface as well To set up a new VLAN interface you will need to do the following Go to the Configuration System IP page Once there you can click on the Add Interface button which will allow you to add a new IP in terface Please note You can only have one Interface per subnet You can t use the same VLAN ID twi...

Страница 9: ...Trunk o Port VLAN ID you used to set up the IP interface o Port Type C Port can t be changed under this Mode o Ingress Filtering Selected can t be changed under this Mode o Ingress Acceptance Tagged and Untagged can t be changed under this Mode o Egress Tagging Untag Port VLAN o Allowed VLANs 1 4094 this can be shortened to match your VLAN ID Please note If you need to customise the port type or t...

Страница 10: ...on so the link is active Once you are satisfied with the link click on the save button to commit your changes This setup must be repeated on the destination box using the originator s IP address under the Remote IP box to complete the setup Please ensure that the Link numbers first column match up on both boxes i e if you set up the link under link 3 then you must do the same on the destination bo...

Страница 11: ...ed your network presentation you can set the number of channels you wish to allocate to the logical links to be functional each logical link must have a minimum of one channel To configure this you can either click on the Channel Selection link on the port settings page or you can go directly to the following submenu Configuration CES Link Channel Selection Depending on the network presentation re...

Страница 12: ...uration CES Clock Priorities The lowest number 0 indicates the highest priority whereas the highest 19 indicates the lowest priority The unit will attempt to use the highest priority clock first and if it can t get a stable connection it will move to the next priority in the list until it eventually gets a stable clock connection In a scenario where there is a Liberator unit at each end of a logic...

Страница 13: ...eerun Clock isn t synchronised with any source or destination Acquiring Clock source has been identified and is in the process of synchronising Acquired Clock source has been synchronised and locked Holdover Clock data is using the last known value as insufficient data is being received from the source destination ...

Страница 14: ...Net2Edge Liberator CE Quick Start Guide 14 5 Cable Pinouts RS 232 FM RS 232 M ...

Страница 15: ...Net2Edge Liberator CE Quick Start Guide 15 V35 M V35 FM ...

Страница 16: ...Net2Edge Liberator CE Quick Start Guide 16 X21 FM X21 M ...

Страница 17: ...k Start Guide 17 6 Contacts Corporate Headquarters Net2Edge Limited Passfield Oak LIPHOOK Hampshire GU30 7RL United Kingdom tel 44 345 013 0030 support net2edge com sales net2edge com liberator net2edge com com www net2edge com ...

Отзывы: