4. Establish the DS3 connection.

Plug the DS3 Tx and Rx cables into the corresponding DS3 connection BNC ports on the UIM-DS3 
faceplate. Verify the connection; the DS3 Lnk LED will pulse (once per second) to indicate the DS3 
connection is established and operational.

Additional Information

LED Indicators

 

(A pulsing LED blinks steadily at a rate of once per second. A flashing LED blinks at a more rapid, 
less constant rate.)

Regulatory Compliance

The following regulatory compliance information applies to the UIM-DS3 as installed in a Mini DSLAM 
chassis or as affixed to a MUM installed in an IP DSLAM chassis.

FCC Regulatory Compliance Information for Class A Equipment 

Note: This equipment has been tested and found to comply with the limits for a Class A digital 
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable 
protection against harmful interference when the equipment is operated in a commercial 

NOTE

A DS3 Uplink Interface Module (UIM-DS3) must be connected via DS3 line to a DS3 network extender provider 
unit (DNE4500-P or DNE4500-P-6-AC/DC). A UIM-DS3 connected to a DS3 network extender subscriber unit 
(DNE4500-S) will not function.

LED State

Indication

Additional Information

Lnk

flashing green DS3 is operational

The DS3 connection has been established and traffic is flowing.

solid green

DS3 link is 
established

A connection exists but there is indication of a problem with the DS3 line.

no 
illumination

Red Alarm

The incoming connection to the UIM-DS3 has been lost; no data is being 
received.

Alm

no 
illumination

DS3 is operational

Note: If the DS3 Lnk LED also remains unlit then the UIM-DS3 is in Red 
Alarm.

solid amber

Yellow Alarm

The outgoing connection from the UIM-DS3 has been lost; no data is being 
transmitted.

pulsing amber

Blue Alarm

An indirect connection has been lost; the UIM-DS3 may no longer be 
receiving data.