E1 Loop Bonding Uplink Interface Module

 

 

 
 
 

 

 

1.0   INSTALLATION 

 

1.1   Unpack and Inspect the Equipment 

The following components should be included: 
 

z

  

UIM-2E1  

z

  

#6 Phillips Panhead Nylon Locking Screws  

z

  

#6 Phillips Beige Flathead Screws  

 
If there is any visible damage, do not attempt to connect the device. Contact Customer Support at 1-877-

638-2638 (1-603-427-0600 for international customers) or 

[email protected]

 . 

 

 

1.2   Configure the E1 Ports 

The E1 Configuration Switches for both Port 1 and Port 2 are on the component side of the UIM-2E1 circuit
board, opposite the faceplate/label. When facing the Configuration Switches, Port 1 switches are on the 

left and Port 2 switches are on the right. Switches for both ports are numbered from left to right, #1-8. 
 

 

 

 

1.2.1   Frame Type

 

Frame type is the data encapsulation method. An E1 frame consists of 248 data bits (an 8-bit 
sample of each of the 31 E1 data channels), plus 8 synchronization bits, transmitted at a rate of 
8,000 frames per second across the E1 line. 

Installation Instructions

C

AUTION

Net to Net Technologies strongly recommends the use of proper electrostatic discharge (ESD) precautions when handling 
this equipment. 

N

OTE

Port 2 Configuration Switches on the UIM-2E1 are NOT USED: frame type and line code for Port 2 are determined by 
the Port 1 switch settings. BOTH ports determine speed and timing configurations via communication with the remote 
E1 equipment to which the UIM-2E1 is connected. 

PORT 1 SWITCHES

Switch #

 

Configuration

 

Switch #

 

Configuration

 

1

not used

5

not used

2

not used

6

not used

3

FRAME TYPE

7

not used

4

LINE CODE

8

not used

220-0000083 rev 01