© EUROHEAT DISTRIBUTORS (H.B.S) LTD. June 2008
E & OE Instructions Part number IN1115 Edition G3
8
Changing to Rear Flue Connection
1. Remove the top chamber baffle plate (see page 5). Caution the top chamber baffle is fragile. See operating
instructions for information on removal.
2. Then remove protector baffle plate if fitted (see page 6).
3. Replace the top chamber baffle.
4. Remove flue spigot and spigot protection from top of stove.
5. Some models will require the rear heat shield rear flue access plate to be removed. With a hack saw blade or
similar remove the section from the rear heat shield which covers the rear flue outlet.
6. Remove flue blanking plate from rear of stove.
7. Fit the blanking plate to top of stove with the blanking plate protector. This protection plate is supplied with
cast iron models only (H&S 13,23,33,43).
8. Fit flue spigot to rear of stove (do not fit spigot protector).
Flue Spigot
Gasket
Flue Blanking Plate
Gasket
Blanking Plate
Protector
9. The Nestor Martin R23, R33, RH33, FH33 have an additional top closing plate for the top cover. This is
retained in place by a square steel plate which is supplied with the stove. This plate slides into fixings under
the top removable plate. Once this is fitted the round steel finishing plate can be put into place.
Top flue blanking plate location.
Changing to Top Flue Connection
The procedure is as fitting rear flue but follow the information in reverse and fit the flue spigot protector and
protector baffle plate. (See page 6)
Under side of
top fascia plate
Round fascia
support plate
Round fasica
top blanking