SAMPLE APPLICATIONS AND WIRING DIAGRAMS (Set jumpers as shown)
+
-
TGR
JP5
JP
1
JP
2
JP
3
JP4
R3
N/O
COM
N/C
SEC
MIN
REPEAT
1-SHOT
END
BEGIN
A
B
TRIGGER
MODE
TRIGGER
POLARITY
+
-
TIME 1 - 60
LED
NESS-960
Delay Timer
K1
120VAC
Supply
120V
LIGHT
USING TWO 960'S TO DELAY THEN THEN TOGGLE A RELAY
9
Hot
Neutral
12 Volts DC
Power Supply
-
+
+
-
TGR
JP5
JP
1
JP
2
JP
3
JP4
R3
N/O
COM
N/C
SEC
MIN
REPEAT
1-SHOT
END
BEGIN
A
B
TRIGGER
MODE
TRIGGER
POLARITY
+
-
TIME 1 - 60
LED
NESS-960
Delay Timer
K1
N/O
SWITCH
2
#
1
#
Used for delaying a trigger then toggling a relay on/off. NESS-960 #1 starts a time delay when the N/O switch is closed.
When 960 #1's time delay expires, 960 #2 is triggered turning it's relay on for the time delay setting , then turning the relay
off. (toggle) To sumarize: fire trigger on #1, waits, turns on #2's relay, waits, then turns relay off.
12 Volts DC
Power Supply
SIREN
DOOR PROP ALARM
TIMER
+
-
-
+
3
+
-
TGR
JP5
JP
1
JP
2
JP
3
JP4
R
3
N/O
COM
N/C
SEC
MIN
REPEAT
1-SHOT
END
BEGIN
A
B
TRIGGER
MODE
TRIGGER
POLARITY
+
-
TIME 1 - 60
LED
NESS-960
Delay Timer
K1
Delay is started when the door is opened. If the door
remains opened after the time delay has expired the relay
will turn on and remain on until the door is closed. If the door
is closed before the time delay expires the NESS-960 is reset
awaiting another input from the door contact.
N/C
CONTACT ON
DOOR
INSTANT ACTIVATION OF ZONE
WITH DELAYED RESTORAL
6
+
-
TGR
JP5
JP
1
JP
2
JP
3
JP4
R3
N/O
COM
N/C
SEC
MIN
REPEAT
1-SHOT
END
BEGIN
A
B
TRIGGER
MODE
TRIGGER
POLARITY
+
-
TIME 1 - 60
LED
NESS-960
Delay Timer
K1
N/C
CONTACT
CLOSED
ZONE
CONTROL PANEL
-
+
12V AUX
22K Ohm
Resistor
When contact opens, relay is turned on which causes
instant zone violation. Contact reclosure will cancel trigger
applied by resistor. Delay starts when contact closes.
Relay turns off and zone restores after delay time expires.
+
-
TGR
JP5
JP
1
JP
2
JP
3
JP4
R3
N/O
COM
N/C
SEC
MIN
REPEAT
1-SHOT
END
BEGIN
A
B
TRIGGER
MODE
TRIGGER
POLARITY
+
-
TIME 1 - 60
LED
NESS-960
Delay Timer
K1
120VAC
Supply
Motion
Detector
N/C
COM
120V
LIGHT
AUTOMATIC LIGHT
CONTROL
4
Hot
Neutral
+
-
22K Ohm
Resistor
12 Volts DC
Power Supply
-
+
For turning on an interior or exterior light with a motion
detector. When motion is detected, the NESS-960 is triggered
and the light is turned on. The amount of time the light remains
on after the detector resets is adjustable. Delay time will
automatically restart each time the motion detector activates.
+ ARMED
OUTPUT
+
-
TGR
JP5
JP
1
JP
2
JP
3
JP4
R3
N/O
COM
N/C
SEC
MIN
REPEAT
1-SHOT
END
BEGIN
A
B
TRIGGER
MODE
TRIGGER
POLARITY
+
-
TIME 1 - 60
LED
NESS-960
Delay Timer
K1
EXIT DELAY
SHUNT TIMER
5
CLOSED
ZONE
INPUT
CONTROL PANEL
-
+
12V AUX
N/C
CONTACT ON
EXIT DOOR
Provides an exit delay to an otherwise instant alarm loop.
The NESS-960 is triggered by the control's Armed output. The
door contact is then shunted by the relay contacts. After the
user has exited and the delay time has expired, the door
contact is restored into the loop.
BELL OR LIGHT
FLASHER
12V
LIGHT
or LED
+
-
+
-
TGR
JP5
JP
1
JP
2
JP
3
JP4
R3
N/O
COM
N/C
SEC
MIN
REPEAT
1-SHOT
END
BEGIN
A
B
TRIGGER
MODE
TRIGGER
POLARITY
+
-
TIME 1 - 60
LED
NESS-960
Delay Timer
K1
8
12V ALARM
OUTPUT
-
+
CONTROL PANEL
12V Bell
or Siren
+
-
Converts a steady output to pulsing, suitable for flashing a light
or pulsing an audible device. Note: Alarm output must be
capable of supplying enough current to drive the bell and light.
ALARM CUT-OFF
TIMER
12V Bell
or Siren
+
-
12V ALARM
OUTPUT
-
+
CONTROL PANEL
7
+
-
TGR
JP5
JP
1
JP
2
JP
3
JP4
R3
N/O
COM
N/C
SEC
MIN
REPEAT
1-SHOT
END
BEGIN
A
B
TRIGGER
MODE
TRIGGER
POLARITY
+
-
TIME 1 - 60
LED
NESS-960
Delay Timer
K1
Useful for adding a cut-off timer to a control panel that does
not have one. It can also be used to shorten the cut-off timer
for a control with no adjustable timer.
12/24V
MAGLOCK
MAGLOCK RELEASE
TIMER
+
-
2
+
-
TGR
JP5
JP
1
JP
2
JP
3
JP4
R
3
N/O
COM
N/C
SEC
MIN
REPEAT
1-SHOT
END
BEGIN
A
B
TRIGGER
MODE
TRIGGER
POLARITY
+
-
TIME 1 - 60
LED
NESS-960
Delay Timer
K1
12/24 Volts DC
Power Supply
-
+
N/O
Pushbutton
Used to extend the release time of an access control device
or to manually activate a door
maglock
release device. The
trigger is activated by a contact closure or a N/O pushbutton
and the door maglock remains released (door open) after the
button is released for the delay time set up in the NESS-960.
12/24 Volts DC
Power Supply
12/24V
DOOR
STRIKE
DOOR STRIKE HOLD
TIMER
+
-
-
+
1
+
-
TGR
JP5
JP
1
JP
2
JP
3
JP4
R
3
N/O
COM
N/C
SEC
MIN
REPEAT
1-SHOT
END
BEGIN
A
B
TRIGGER
MODE
TRIGGER
POLARITY
+
-
TIME 1 - 60
LED
NESS-960
Delay Timer
K1
N/O
Pushbutton
Used to extend the release time of an access control device
or to manually activate a door
strike
release device. The
trigger is activated by a contact closure or a N/O pushbutton
and the door strike remains activated (door open) after the
button is released for the delay time set up in the NESS-960.