7
Programming
Programming will vary depending on access configuration. Follow the instructions according to your access
configuration.
Notes:
User ID number
: Assign a user ID to the access card / PIN in order to track it. The common user ID number can
be any number from 0~997, the panic user ID is from 998~999. IMPORTANT: User IDs do not have to be
proceeded with any leading zeros. Recording of User ID is critical. Modifications to the user require the User ID
be available.
Proximity Card
:
EM version: 125KHz industry standard 26bits EM card
PIN:
Can be any 4~6 digits except 8888 which is reserved.
Add Common Users
Programming Step
Keystroke Combination
1. Enter Program Mode
*
(Master Code) #
Add Card User
2. Add Card: Using Auto ID
(Allows XK Series device to assign Card to
next available User ID number)
OR
2. Add Card: Select Specific ID
(Allows Master to define a specific User ID to
associate the card to)
OR
2. Add Card: by Card Number
OR
2. Add Card: Block Enrolment
(Allows Master to add up to 998 cards to the
Reader in a single step)
Takes 2 minutes to program.
1 (Read Card) #
The cards can be added continuously.
1 (User ID) # (Read Card) #
(User ID is any number from 0-997)
1 (Input 8/10 digits Card number) #
1 ( User ID) # (Card quantity) # (The first
card number) #
Cards’ number must be consecutive;
Card quantity = number of cards to be enrolled.
Add PIN User
2. Add PIN: Using Auto ID
(Allows XK Series device to assign PIN to next
available User ID number)
1 (PIN ) #
The PINs can be added continuously.
(PIN: 4~6 digits)
2. Add PIN: Select Specific ID
(Allows manager to define a specific User ID
to associate the PIN to)
1 (User ID) # (PIN ) #
The user ID is any number from 0-997.
3. Exit
*